EasyManua.ls Logo

Rheem IKONIC RTGH-SR84i - Water Inlet Connection 3;4

Rheem IKONIC RTGH-SR84i
92 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
IKONIC Tankless Water Heater Service Manual
71
3.5 WATER INLET CONNECTION ¾"
HOW TO REMOVE COMPONENTS
1. Remove 3 screw from the bottom plate, as pictured
below.
2. Remove a screw holding freeze protection heater
from water inlet connection.
3. Remove quick fastener connected to check valve.
NOTE: If for non recirculation model, remove
quick fastener connected water valve.
Check Valve
NOTE: Before removing water inlet connection, turn off water to the water heater by closing the
shut off valve and drain the heater.