AIR COOLED
CONDENSING UNITS
92-104921-09-07 (5/16)
Printed in USA
[ ] indicates metric conversions.
Do not destroy this manual.
Please read carefully
and keep in a safe place
for future reference by a
serviceman.
WARNING
THESE INSTRUCTIONS
ARE INTENDED AS AN AID
TO QUALIFIED, LICENSED
SERVICE PERSONNEL FOR
PROPER INSTALLATION,
ADJUSTMENT, AND
OPERATION OF THIS
UNIT. READ THESE
INSTRUCTIONS
THOROUGHLY
BEFORE ATTEMPTING
INSTALLATION OR
OPERATION. FAILURE
TO FOLLOW THESE
INSTRUCTIONS MAY
RESULT IN IMPROPER
INSTALLATION,
ADJUSTMENT, SERVICE,
OR MAINTENANCE
POSSIBLY RESULTING IN
FIRE, ELECTRICAL SHOCK,
PROPERTY DAMAGE,
PERSONAL INJURY, OR
DEATH.
INSTALLATION INSTRUCTIONS
(-)A13, (-)A14 & (-)A16 MODEL SERIES –
13, 14 & 16 SEER
WARNING:
RECOGNIZE THIS SYMBOL
AS AN INDICATION OF
IMPORTANT SAFETY
INFORMATION
ST-A1226-01-00
FEATURING INDUSTRY STANDARD
R-410A REFRIGERANT
earth friendly refrigerant
e
ar
t
h
r
y r
dly
dl
e
n
i
fr
h
NOTE: Actual unit appearance
may vary.

Table of Contents

Questions and Answers:

Rheem RA1360AD1NB Specifications

General IconGeneral
Tonnage3 Ton
RefrigerantR-410A
Compressor TypeScroll
Voltage208/230V
Phase1
Maximum Overcurrent Protection40 A
TypeSplit System
Cooling Capacity36000 BTU/h
Sound Level (Outdoor Unit)76 dB

Summary

IMPORTANT SAFETY INFORMATION

AWARNINGS

General safety warnings and precautions for installation and operation.

ACAUTIONS

Specific cautionary notes regarding R-410A systems and components.

Specifications

Proper Installation

Importance of correct sizing and installation for optimal performance and efficiency.

INSTALLATION

Tools and Refrigerant

List of tools and refrigerant information required for R-410A models.

Interconnecting Tubing

Practices for installing tubing between indoor and outdoor units.

Refrigerant Level Adjustment

Procedures for adjusting refrigerant charge based on line set length and configuration.

Tubing Installation

Guidelines for installing refrigerant tubing between the condensing unit and evaporator coil.

Leak Testing

Method for testing the system for refrigerant leaks after installation.

WIRING

Grounding

Critical safety requirement for properly grounding the unit.

START-UP

Evacuation Procedure

Critical steps for removing air and moisture from the system.

Final Leak Testing

Using a leak detector to check for leaks after evacuation and system pressurization.

Checking Refrigerant Charge

Procedures for verifying and adjusting the system's refrigerant charge.

Charging Units With R-410A Refrigerant

Specific considerations for charging R-410A systems due to higher pressures.

Final Charge by Subcooling

Method for fine-tuning the refrigerant charge using subcooling measurements.

DIAGNOSTICS

Electrical Checks Flowchart

Troubleshooting guide for diagnosing electrical issues affecting unit operation.

Cooling Mechanical Checks Flowchart

Troubleshooting guide for diagnosing mechanical problems during cooling operation.

General Troubleshooting Chart

Comprehensive chart correlating symptoms with possible causes and remedies.

Cooling Mode Troubleshooting Tips

Quick reference for diagnosing common cooling system problems based on indicator readings.