Description
Return Valve 2 Pool/Spa Pool User Select the position of a 3-way valve located
between the heater and the Pool/Spa for this
scheduled pump period.
Suction Valve 2 Pool/Spa Pool User Select the position of the 3-way valve located
between the Pool/Spa and the Pump for this
scheduled pump period.
Pump On Time 3 12:00A–11:59P User
Select ON time for Pump Period #3 to take
e󰀨ect.
Pump O󰀨 Time 3 12:00A–11:59P User Select OFF time for Pump Period #3 to stop.
Pump Speed 3
1–4 if 4-Speed
Enabled
0%–100% if Variable
Enabled
User
On 4-speed pumps, this denotes the selected
pump output (which connects to the pump for
the selected speed) for this pump period. On
variable-speed pumps, this denotes the PWM
signal to be provided to the pump for pump
operation.
Return Valve 3 Pool/Spa Pool User
Select the position of a 3-way valve located
between the heater and the Pool/Spa for this
scheduled pump period.
Suction Valve 3 PoolSpa Pool User
Select the position of the 3-way valve located
between the Pool/Spa and the Pump for this
scheduled pump period.
Pump On Time 4 12:00A–11:59P User
Select ON time for Pump Period #4 to take
e󰀨ect.
Pump O󰀨 Time 4 12:00A–11:59P User Select OFF time for Pump Period #4 to stop.
Pump Speed 4
1–4 if 4-Speed
Enabled
0%–100% if Variable
Enabled
User
On 4-speed pumps, this denotes the selected
pump output (which connects to the pump for
the selected speed) for this pump period. On
variable-speed pumps, this denotes the PWM
signal to be provided to the pump for pump
operation.
Return Valve 4 Pool/Spa Pool User
Select the position of a 3-way valve located
between the heater and the Pool/Spa for this
scheduled pump period.
Suction Valve 4 Pool/Spa Pool User
Select the position of the 3-way valve located
between the Pool/Spa and the Pump for this
scheduled pump period.