26
Item Range
Default
Value
Access
Level
Description
Pump O󰀨 Time 3 12:00A–11:59P Installer Select OFF time for Pump Period #3 to stop.
Pump Speed 3
1–4 if 4-Speed
Enabled
0%–100% if Variable
Enabled
Installer
On 4-speed pumps, this denotes the selected
pump output (which connects to the pump for
the selected speed) for this pump period. On
variable-speed pumps, this denotes the PWM
signal to be provided to the pump for pump
operation.
Return Valve 3 Pool/Spa Pool Installer
Select the position of a 3-way valve located
between the heater and the Pool/Spa for this
scheduled pump period.
Suction Valve 3 Pool/Spa Pool Installer
Select the position of the 3-way valve located
between the Pool/Spa and the Pump for this
scheduled pump period.
Pump On Time 4 12:00A–11:59P Installer
Select ON time for Pump Period #4 to take
e󰀨ect.
Pump O󰀨 Time 4 12:00A–11:59P Installer Select OFF time for Pump Period #4 to stop.
Pump Speed 4
1–4 if 4-Speed
Enabled
0%–100% if Variable
Enabled
Installer
On 4-speed pumps, this denotes the selected
pump output (which connects to the pump for
the selected speed) for this pump period. On
variable-speed pumps, this denotes the PWM
signal to be provided to the pump for pump
operation.
Return Valve 4 Pool/Spa Pool Installer
Select the position of a 3-way valve located
between the heater and the Pool/Spa for this
scheduled pump period.
Suction Valve 4 Pool/Spa Pool Installer
Select the position of the 3-way valve located
between the Pool/Spa and the Pump for this
scheduled pump period.
Faults Last
Installer/
Service
Fault history starting with the most recent
and going back to 10 last faults. Using the
UP/DOWN buttons scrolls through the fault
history. If there are no faults present, the
display will read “All Faults Clear”.
Clear Faults
Installer/
Service
Holding down the UP and DOWN buttons for
3+ seconds clears the recorded fault history
and “Faults Cleared” appears on the display.
Run Hours
XXXX
Cycles
XXXX
Installer/
Service
Displays the number of run hours that the
compressor has been running as well as the
number of cycles that the unit has operated.