EasyManua.ls Logo

Rheem Raypak CROSSWIND V Series - Page 33

Rheem Raypak CROSSWIND V Series
89 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
33
7. Activate remote mode in the heater. Press and hold
the UP and DOWN arrow keys simultaneously for 3
to 5-seconds.
BLUE - 24VAC OUTPUT
REMOTE CONTROLLER
POOL AND SPA
OPERATION
POOL AND SPA
COMMANDS
P16
P7
P1
P16
P7
P1
P16
P7
P1
REMOTE
Figure 58. 3-Wire Remote Harness Installation
Remote Control Options for Heat/Cool
Models
In Heat/Cool models, the 3-wire remote "Pool" terminal
can be congured to operate as "Pool Heat", "Pool Cool"
or "Pool Auto". The default mode for remote pool is "Pool
Heat".
1. To change this setting enter "Program Menu" by
pressing and holding SERVICE + MODE keys
simultaneously for 7-10 seconds.
2. Press SERVICE key until "Remote Pool Mode" is
displayed.
3. Use the UP or DOWN keys to select "Pool Cool",
"Pool Auto" or "Pool Heat".
4. After selection is completed, press MODE key to exit
the "Program Menu".
5. For remote controllers without its own thermostat,
use the MODE key to select the pool mode (pool
heat, pool cool or pool auto). Then use the UP/
DOWN keys to adjust the temperature setpoint to be
used in remote mode.
6. For remote controller with its own thermostat, push
the MODE key to select the pool mode (pool heat,
pool cool or pool auto) and set the temperature
setpoints to the highest/lowest setting available on
the heater. The actual setpoint will be controlled by
the remote controller.
7. Turn "OFF" with MODE key and remove power from
the heater.
8. For a 2-Wire remote control, connect the BLUE wire
to one side of the remote controller and connect the
other side to the BLACK/ORANGE wire for "POOL"
operation.
9. Attach wire nut on the ORANGE/BLACK wire of the
3-wire remote harness. See Figure 59.
POOL MODE
SELECTOR
REMOTE CONTROLLER
POOL ON/OFF
BLUE - 24VAC OUTPUT
WIRE NUT ORN/BK
3A 3A
P16
USER INTERFACE
P7
REMOTE
SELECTOR
POWER
24VAC
P1
MAIN
FUSE
VALVES
F1
F2
3A 3A
P16
USER INTERFACE
P7
REMOTE
SELECTOR
POWER
24VAC
P1
MAIN
FUSE
VALVES
F1
F2
3A 3A
P16
USER INTERFACE
P7
REMOTE
SELECTOR
POWER
24VAC
P1
MAIN
FUSE
VALVES
F1
F2
REMOTE
Figure 59. 2-Wire Remote Harness Installation
10. For 3-wire control, connect the BLUE wire to one side
of the remote controller and connect the ORANGE/
BLACK wire for "SPA" operation and the BLACK/
ORANGE wire for the "POOL" operation. See Figure
58.
11. Install the 3-wire remote harness to the "P7" connector
and turn power ON to the heater.
12. Activate remote mode in the heater. Press and hold
the UP and DOWN arrow keys simultaneously for 3
to 5-seconds.