53
Main View
• The main view of Raymote display a list of the heaters
added in to your Raymote Organization.
• Each heater is represented by a tile with its name and
an overview of the heater operation parameters.
USER AND ORGANIZATION
SETTINGS
ADD HEATERS AND
SORTING
HEATER LIST CAN
INCLUDE COMMERCIAL
HEATERS
OPENS NOTIFICATIONS
SCREEN
OPENS AUTOMATION
SCREEN
HEATERS SCREEN
HEATER OFFLINE
INDICATOR
CURRENT WATER
TEMPERATURE
HEATER NAME
HEATER MODE
SELECTION
WATER TEMPERATURE
TARGET
Crosswind V Heat Pump
Figure 86. Main View - Heaters List
• Raymote organization list can handle 1 or multiple
Commercial and Residential Raypak heaters
equipped with Raymote. See Figure 86.
Heater Name
• Heater name is defined during the heater connection
and setup, but it can be changed anytime from the
heater settings.
Water Temp
• The water temperature measured by the heater is
displayed in this field. Water Temp variates with the
ambient temperature, pumps and heater's operation.
Setpoint
• Setpoint is the goal temperature for the heater. It can
be adjusted from the Crosswind V control board or
directly from Raymote.
• Heater start a call-for-heat when Water Temp is 1
degree Fahrenheit or more, below the setpoint and
operation Mode is POOL or SPA.
• In heat/cool models, Pool cool mode, heater starts to
cool when water is 1°F above temperature setpoint.
• In heat/cool models, Pool auto mode, heater starts to
cool when water temp is above temperature setpoint
+ cooling deadband. In this mode, unit call-for-heat if
water temperature is 1°F below temperature setpoint.
• Heater terminates heat when Water Temp is equal or
greater the setpoint temperature, or when Mode is
changed to OFF.
Mode
• Mode field displays the current operation mode
selected.
• POOL mode use an independent setpoint. Heat/
Cool models include POOL COOL and POOL AUTO
modes.
• SPA and TIMED SPA modes use an independent
setpoint.
• In OFF mode the heater is operational but is
maintained in standby until mode changes to POOL
or SPA.
Ofine Indicator
• The offline indicator is displayed only when the heater
can not be detected online.
• Offline status can be cause by a heater disconnected
from power, Wi-Fi signal weak or not available, or
due to any change in Wi-Fi signal name or password.
• Check the Connectivity Troubleshooting section for
details on how to recover or reconnect a heater to
Raymote.