INSTALLATION INSTRUCTIONS
92-20521-44-06
SUPERSEDES 92-20521-44-05
WARNING
WARNING
!
These instructions are intended as an aid to qualified licensed
service personnel for proper installation, adjustment and
operation of this unit. Read these instructions thoroughly before
attempting installation or operation. Failure to follow these
instructions may result in improper installation, adjustment,
service or maintenance possibly resulting in fire, electrical
shock, property damage, personal injury or death.
ISO 9001:2008
AIR HANDLERS
(-)BHP
MODELS FEATURING R-22 REFRIGERANT
MODELS FEATURING EARTH-FRIENDLY R-410A REFRIGERANT
MODELS FEATURING ELECTRIC HEAT WITHOUT INDOOR
COOLING COIL
refrigerant
Question and Answer IconNeed help?

Do you have a question about the Rheem RBHP-17J06SH1 and is the answer not in the manual?

Rheem RBHP-17J06SH1 Specifications

General IconGeneral
BrandRheem
ModelRBHP-17J06SH1
Phase1
Height21 in
CategoryAir Handler
Cooling Capacity17, 000 BTU/h
RefrigerantR410A
Filter Size16 x 20 x 1
Refrigerant Connections3/8" x 5/8"
Drain Connection Size3/4"
Depth46.5 in

Summary

1.0 SAFETY INFORMATION

3.0 ELECTRICAL WIRING

3.1 POWER WIRING

Covers requirements for proper electrical power connection, including disconnects and conductor sizing.

3.2 CONTROL WIRING

Details requirements for low voltage control wiring, routing, and separation from power wiring.

3.3 GROUNDING

Explains the importance of permanent grounding and methods for achieving it.

3.4 BLOWER MOTOR ELECTRICAL DATA: “A” VOLTAGE (115V)

Provides electrical specifications for blower motors operating on 115V.

3.5 BLOWER MOTOR ELECTRICAL DATA: “J” VOLTAGE (208/240V)

Provides electrical specifications for blower motors operating on 208/240V.

3.6 ELECTRIC HEAT ELECTRICAL DATA

Lists electrical data for electric heaters, including kW, voltage, and circuit requirements.

4.0 DUCTWORK

5.0 REFRIGERANT CONNECTIONS

6.0 CONDENSATE DRAIN TUBING

8.0 AIRFLOW PERFORMANCE

8.1 AIRFLOW OPERATING LIMITS

Provides tables for maximum, nominal, and minimum airflow limits for different unit sizes and tonnages.

8.2 AIRFLOW PERFORMANCE DATA

Presents detailed airflow performance data based on blower motor speed and external static pressure.

9.0 SEQUENCE OF OPERATION

9.4 WATT RESTRICTOR (HEATING - HEAT PUMP)

Explains the function of the watt restrictor in controlling supplemental electric heat based on heat pump performance.

9.5 DEFROST SEQUENCE

Covers the defrost sequence for heat pumps, including supplemental heat during defrost.

11.0 PRESTART CHECKLIST

12.0 MAINTENANCE

Related product manuals