Do you have a question about the Rheem RBHP-17A00NH1 and is the answer not in the manual?
Model Number | RBHP-17A00NH1 |
---|---|
Category | Air Handlers |
Refrigerant | R-410A |
Voltage | 208/230V |
Phase | 1 |
Frequency | 60 Hz |
Motor Type | PSC |
Width (in) | 21 |
Cooling Capacity | 17000 BTU |
Heating Capacity | 17000 BTU |
Filter Type | Standard |
Covers essential safety precautions, potential hazards, and warnings for installation and operation.
Discusses the importance of duct system balance and sealing for efficiency and indoor air quality.
Procedures for inspecting delivered units, checking rating plates, and reading instructions before installation.
Details required clearances for combustible materials, ductwork, and floor bases based on unit specifications.
Explains the composition of the unit model number and lists available configurations.
Provides physical dimensions, weight data, and duct connection sizes for various cabinet models.
Describes modular construction and steps for disassembling the unit for installation purposes.
Details connections and considerations for vertical upflow unit configurations.
Instructions for converting units to vertical downflow, including coil and breaker adjustments.
Guidelines for configuring units for horizontal airflow, including drain pan setup.
Covers power supply, branch circuit disconnects, conductor types, and wiring connections for the unit.
Procedures for routing and separating low-voltage control wiring from power wiring.
Explains the critical steps for properly grounding the unit to prevent electrical shock.
Provides specific electrical data for 115V blower motors, including amps and capacity.
Provides specific electrical data for 208/240V blower motors, including amps and capacity.
Details electrical specifications for electric heating elements, including kW ratings and circuit requirements.
Guidance on selecting and installing flowcheck pistons based on coil and unit combinations.
Lists maximum, nominal, and minimum CFM for various unit sizes and capacities.
Detailed airflow performance data at different static pressures and speed settings.
Describes the sequence of operations for cooling mode in the unit.
Details the sequence of operations for electric heat-only heating mode.
Explains the sequence of operations for heat pump heating mode.
Explains the watt restrictor's role in managing supplemental electric heat during heat pump operation.
Instructions for engaging and operating the unit in emergency heat mode.
Guidance on thermostat mounting and proper setting of heat anticipators.
Provides the formula for calculating air temperature rise for electric resistance heat.
Provides the formula for calculating BTUH heating capacity for electric resistance heat.
Provides the formula for calculating airflow based on temperature rise and heating BTUH.
Instructions for inspecting, cleaning, or replacing the air filter to ensure proper system operation.
Procedures for cleaning the indoor coil, drain pan, and drain line to prevent issues.
Guidance on inspecting and cleaning the blower motor and wheel for optimal airflow.
Steps for removing and replacing the blower assembly for component access or cleaning.
Detailed steps for safely removing and replacing electric heater elements.
Step-by-step instructions for removing and replacing the indoor blower motor.