10
F
IGURE 3B
DIMENSIONS AND WEIGHTS
2.5.2 DIMENSIONS & WEIGHTS: (-)H1T MODELS
A-1038-01
NOTE: 24" CLEARANCE REQUIRED
IN FRONT OF UNIT FOR FILTER
AND COIL MAINTENANCE.
E
LECTRICAL CONNECTIONS MAY
EXIT TOP OR EITHER SIDE
HIGH VOLTAGE CONNECTION 7/8",
1
3/32", 1 31/32" DIA. KNOCK OUTS.
L
OW VOLTAGE CONNECTION
5
/8" AND 7/8" KNOCK OUT
(OUTSIDE OF CABINET)
F
LANGES ARE PROVIDED
FOR FIELD INSTALLATION
A
UXILIARY DRAIN CONNECTION
3/4" FEMALE PIPE THREAD (NPT)
H
ORIZONTAL APPLICATION ONLY
P
RIMARY DRAIN CONNECTION
3/4" FEMALE PIPE THREAD (NPT)
AUXILIARY DRAIN CONNECTION
3/4" FEMALE PIPE THREAD (NPT)
UPFLOW/DOWNFLOW APPLICATION
ONLY
LIQUID LINE CONNECTION
COPPER (SWEAT)
VAPOR LINE CONNECTION
COPPER (SWEAT)
21
11
/16
10
5
/1
6
SUPPLY AIR
W
A
H
19
1
/2
RETURN AIR
OPENING
UPFLOW UNIT SHOWN;
UNIT MAY BE INSTALLED UPFLOW, DOWNFLOW. HORIZONTAL RIGHT, OR LEFT AIR SUPPLY.
Return Air Return Air Opening
Model
Opening Width Depth/Length
Cabinet Size
(Inches) (Inches)
17 15
7
8 19
3
4
21 19
3
8 19
3
4
24 22
7
8 19
3
4
Return Air Opening Dimensions
MODEL
SIZE
(-)H1T
LIQUID
REFRIGERANT CONNECTIONS
SWEAT (IN.) [mm] ID
VAPOR
UNIT
WIDTH
“W” IN.
[mm]
SUPPLY
DUCT
“A” IN.
[mm]
LO HI
UNIT WITH
COIL (MAX. kW.)
NOMINAL CFM
[L/s]
UNIT WEIGHT / SHIPPING
WEIGHT (LBS.) [kg]
UNIT
HEIGHT
IN. [mm]
DIMENSIONAL DATA
2417S
3
/8" [9.53]
3
/4" [19.05] 42
1
/2" [1080] 17
1
/2" [445] 16" [409] 600 [283] 800 [378] 92/106 [42/48]
3617S
3
/8" [9.53]
3
/4" [19.05] 42
1
/2" [1080] 17
1
/2" [445] 16" [409] 1000 [472] 1200 [566] 96/110 [44/50]
3621M
3
/8" [9.53]
7
/8" [22.23] 50
1
/2" [1282] 21" [533] 19
1
/2" [495] 1000 [472] 1200 [566] 126/142 [57/64]
3621H
3
/8" [9.53]
7
/8" [22.23] 57 [1448] 21" [533] 19
1
/2" [495] 1000 [472] 1200 [566] 137/149 [62/68]
4821S
3
/8" [9.53]
7
/8" [22.23] 50
1
/2" [1282] 21" [533] 19
1
/2" [495] 1400 [661] 1600 [755] 128/144 [56/65]
4821M
3
/8" [9.53]
7
/8" [22.23] 57 [1448] 21" [533] 19
1
/2" [495] 1400 [661] 1600 [755] 139/151 [63/68]
4824S
3
/8" [9.53]
7
/8" [22.23] 50
1
/2" [1282] 24
1
/2" [622] 23" [585] 1600 [755] 142/160 [64/72]
6021S
3
/8" [9.53]
7
/8" [22.23] 57 [1448] 21" [533] 19
1
/2" [495] 1600 [755] 1725 [814] 139/151 [63/68]
6024S
3
/8" [9.53]
7
/8" [22.23] 55
1
/2" [1410] 24
1
/2" [622] 23" [585] — 1800 [850] 159/176 [72/80]
(
SEE DUCT FLANGES, SECTION 3.5,
FOR INSTRUCTIONS)

Related product manuals