8
2.4 DIMENSIONS & WEIGHTS (SEE FIGURE 3)
FIGURE 3
DIMENSIONS AND WEIGHTS -- SINGLE COIL UNITS
DIMENSIONAL DATA
A-1038-01
NOTE: 24" CLEARANCE REQUIRED
IN FRONT OF UNIT FOR FILTER
AND COIL MAINTENANCE.
ELECTRICAL CONNECTIONS
MAY EXIT TOP OR EITHER SIDE
HIGH VOLTAGE CONNECTION 7/8".
1 3/32", 1 31/32" DIA. KNOCK OUTS.
LOW VOLTAGE CONNECTION
5/8" AND 7/8" KNOCK OUT
AUXILIARY DRAIN CONNECTION
3/4" FEMALE PIPE THREAD (NPT)
HORIZONTAL APPLICATION ONLY
PRIMARY DRAIN CONNECTION
3/4" FEMALE PIPE THREAD (NPT)
AUXILIARY DRAIN CONNECTION
3/4" FEMALE PIPE THREAD (NPT)
UPFLOW/DOWNFLOW APPLICATION
ONLY
LIQUID LINE CONNECTION
COPPER (SWEAT)
VAPOR LINE CONNECTION
COPPER (SWEAT)
21
11
/16
10
5
/16
SUPPLY AIR
W
A
H
19
1
/2
RETURN AIR OPENING
UPFLOW UNIT SHOWN;
UNIT MAY BE INSTALLED UPFLOW, DOWNFLOW.
HORIZONTAL RIGHT, OR LEFT AIR SUPPLY.
Model Return Air Opening Return Air Opening
Cabinet Size Width (Inches) Depth/Length (Inches)
21 19
3
8 19
1
2
24 22
7
8 19
1
2
RETURN AIR OPENING DIMENSIONS
RHPL-HM
UNIT WIDTH
“W” IN. [mm]
UNIT HEIGHT
“H” IN. [mm]
SUPPLY DUCT
“A” IN. [mm]
ODD* ODD*Normal Normal
1
ST
STAGE 2
ND
STAGE
NOMINAL COIL AIRFLOW [L/s]
UNIT WITH COIL
(MAX. Kw.)
UNIT WEIGHT / SHIPPING
WEIGHT (LBS.) [kg]
2421 21 [533] 42 1/2 [1080] 19 1/2 [495] 480 [227] 625 [295] 640 [302] 775 [366] 92 / 106 [42 / 48]
3621 21 [533] 42 1/2 [1080] 19 1/2 [495] 720 [340] 900 [425] 960 [453] 1200 [566] 92 / 106 [42 / 48]
4824 24 1/2 [622] 55 1/2 [1410] 23 [584] 960 [453] 1200 [566] 1280 [604] 1625 [767] 162 / 180 [73 / 82]
6024 24 1/2 [622] 55 1/2 [1410] 23 [584] 1040 [491] 1375 [649] 1360 [642] 1675 [791] 181 / 198 [82 / 90]
*Maximum dehumidification airflow. Refer to Section 5.0 ECM Motor Interface Control Board, for more information.

Table of Contents