COOLING PERFORMANCE DATA—RJNA-A060
HEATING PERFORMANCE DATA—RJNA-A060
DR —Depression ratio
dbE —Entering air dry bulb
wbE—Entering air wet bulb
Total —Total capacity x 1000 BTUH
Sens —Sensible capacity x 1000 BTUH
Power—KW input
NOTES:
When the entering air dry bulb is other than 80°F [27°C], adjust the sensible
capacity from the table by adding [1.10 x CFM x (1 – DR) x (dbE – 80)].
IDB—Indoor air dry bulb [ ] Designates Metric Conversions
ENTERING INDOOR AIR @ 80°F [26.7°C] dbE
wbE 71°F [21.7°C] 67°F [19.4°C] 63°F [17.2°C]
CFM [L/s] 2500 [1180] 2000 [944] 1500 [708] 2500 [1180] 2000 [944] 1500 [708] 2500 [1180] 2000 [944] 1500 [708]
DR
.22 .19 .15 .22 .19 .15 .22 .19 .15
O
U
T
D
O
O
R
D
R
Y
B
U
L
B
T
E
M
P
E
R
A
T
U
R
E
°F
[°C]
75
[23.9]
Total BTUH [kW]
Sens BTUH [kW]
Power
74.9 [21.95]
44.2 [12.95]
4.0
71.6 [20.98]
39.6 [11.61]
3.9
68.4 [20.05]
35.0 [10.26]
3.8
71.3 [20.90]
53.4 [15.65]
3.9
68.2 [19.99]
47.8 [14.01]
3.9
65.1 [19.08]
42.3 [12.40]
3.8
67.6 [19.81]
57.5 [16.85]
3.9
64.6 [18.93]
51.5 [15.09]
3.8
61.7 [18.08]
45.5 [13.33]
3.8
80
[26.7]
Total BTUH [kW]
Sens BTUH [kW]
Power
74.4 [21.80]
44.3 [12.98]
4.2
71.2 [20.87]
39.7 [11.63]
4.1
67.9 [19.90]
35.0 [10.26]
4.1
70.8 [20.75]
53.5 [15.68]
4.2
67.7 [19.84]
47.9 [14.04]
4.1
64.6 [18.93]
42.3 [12.40]
4.0
67.1 [19.67]
57.6 [16.88]
4.1
64.2 [18.82]
51.5 [15.09]
4.1
61.2 [17.94]
45.5 [13.33]
4.0
85
[29.4]
Total BTUH [kW]
Sens BTUH [kW]
Power
73.3 [21.48]
43.8 [12.84]
4.5
70.2 [20.57]
39.2 [11.49]
4.4
67.0 [19.64]
34.7 [10.17]
4.3
69.7 [20.43]
53.0 [15.53]
4.4
66.7 [19.55]
47.5 [13.92]
4.3
63.6 [18.64]
41.9 [12.28]
4.2
66.0 [19.34]
57.1 [16.73]
4.4
63.1 [18.49]
51.1 [14.98]
4.3
60.3 [17.67]
45.2 [13.25]
4.2
90
[32.2]
Total BTUH [kW]
Sens BTUH [kW]
Power
71.8 [21.04]
43.0 [12.60]
4.7
68.7 [20.13]
38.5 [11.28]
4.6
65.6 [19.23]
34.0 [9.96]
4.5
68.2 [19.99]
52.2 [15.30]
4.6
65.2 [19.11]
46.7 [13.69]
4.5
62.3 [18.26]
41.3 [12.10]
4.4
64.5 [18.90]
56.3 [16.50]
4.6
61.7 [18.08]
50.4 [14.77]
4.5
58.9 [17.26]
44.5 [13.04]
4.4
95
[35]
Total BTUH [kW]
Sens BTUH [kW]
Power
70.0 [20.51]
41.9 [12.28]
4.9
67.0 [19.64]
37.5 [10.99]
4.8
63.9 [18.73]
33.2 [9.73]
4.7
66.4 [19.46]
51.1 [14.98]
4.8
63.5 [18.61]
45.8 [13.42]
4.7
60.6 [17.76]
40.4 [11.84]
4.6
62.7 [18.38]
55.2 [16.18]
4.8
60.0 [17.58]
49.4 [14.48]
4.7
57.2 [16.76]
43.7 [12.81]
4.6
100
[37.8]
Total BTUH [kW]
Sens BTUH [kW]
Power
68.0 [19.93]
40.7 [11.93]
5.1
65.1 [19.08]
36.5 [10.70]
5.0
62.1 [18.20]
32.2 [9.44]
4.9
64.4 [18.87]
49.9 [14.62]
5.1
61.6 [18.05]
44.7 [13.10]
5.0
58.8 [17.23]
39.5 [11.58]
4.9
60.7 [17.79]
54.0 [15.83]
5.0
58.1 [17.03]
48.4 [14.18]
4.9
55.4 [16.24]
42.7 [12.51]
4.8
105
[40.6]
Total BTUH [kW]
Sens BTUH [kW]
Power
66.0 [19.34]
39.6 [11.61]
5.4
63.1 [18.49]
35.4 [10.37]
5.3
60.3 [17.67]
31.3 [9.17]
5.1
62.4 [18.29]
48.8 [14.30]
5.3
59.7 [17.50]
43.7 [12.81]
5.2
56.9 [16.68]
38.6 [11.31]
5.1
58.7 [17.20]
52.8 [15.47]
5.3
56.1 [16.44]
47.3 [13.86]
5.2
53.6 [15.71]
41.8 [12.25]
5.1
110
[43.3]
Total BTUH [kW]
Sens BTUH [kW]
Power
64.1 [18.79]
38.5 [11.28]
5.6
61.3 [17.97]
34.5 [10.11]
5.5
58.5 [17.14]
30.5 [8.94]
5.4
60.5 [17.73]
47.7 [13.98]
5.5
57.8 [16.94]
42.7 [12.51]
5.4
55.2 [16.18]
37.8 [11.08]
5.3
56.8 [16.65]
51.8 [15.18]
5.5
54.3 [15.91]
46.4 [13.60]
5.4
51.8 [15.18]
41.0 [12.02]
5.3
115
[46.1]
Total BTUH [kW]
Sens BTUH [kW]
Power
62.4 [18.29]
37.8 [11.08]
5.8
59.7 [17.50]
33.8 [9.91]
5.7
57.0 [16.71]
29.9 [8.76]
5.6
58.8 [17.23]
47.0 [13.77]
5.7
56.2 [16.47]
42.1 [12.34]
5.6
53.7 [15.74]
37.2 [10.90]
5.5
55.1 [16.15]
51.1 [14.98]
5.7
52.7 [15.44]
45.7 [13.39]
5.6
50.3 [14.74]
40.4 [11.84]
5.5
45
[46.1]
Total BTUH [kW]
Power
59.9 [17.55]
3.8
58.9 [17.26]
3.9
57.8 [16.94]
4.1
58.3 [17.09]
4.2
57.3 [16.79]
4.4
56.3 [16.50]
4.5
58.2 [17.06]
4.7
IDB
57.2 [16.76]
4.9
56.2 [16.47]
5.0
60°F [15.5°C]
50
[10]
70°F [21.1°C]
Total BTUH [kW]
Power
63.1 [18.49]
3.9
80°F [26.7°C]
62.0 [18.17]
4.0
60.9 [17.85]
4.1
CFM [L/s]
61.5 [18.02]
4.3
60.4 [17.70]
4.5
2500 [1180] 2000 [944] 1500 [708] 2500 [1180] 2000 [944] 1500 [708] 2500 [1180] 2000 [944] 1500 [708]
59.3 [17.38]
4.6
61.4 [17.99]
4.8
60.4 [17.70]
5.0
59.3 [17.38]
5.1
O
U
T
D
O
O
R
D
R
Y
B
U
L
B
T
E
M
P
E
R
A
T
U
R
E
°F
[°C]
0
[-17.8]
Total BTUH [kW]
Power
16.6 [4.86]
3.0
16.3 [4.78]
3.1
16.0 [4.69]
3.2
15.0 [4.40]
3.4
14.7 [4.31]
3.5
14.4 [4.22]
3.7
14.9 [4.37]
3.9
14.6 [4.28]
4.1
14.4 [4.22]
4.2
5
[26.7]
Total BTUH [kW]
Power
22.7 [6.65]
3.1
22.3 [6.54]
3.2
21.9 [6.42]
3.3
21.1 [6.18]
3.5
20.7 [6.07]
3.6
20.3 [5.95]
3.7
21.0 [6.15]
4.0
20.6 [6.04]
4.2
20.3 [5.95]
4.3
10
[-12.2]
Total BTUH [kW]
Power
28.5 [8.35]
3.2
28.0 [8.21]
3.3
27.5 [8.06]
3.4
26.9 [7.88]
3.6
26.4 [7.74]
3.7
25.9 [7.59]
3.8
26.8 [7.85]
4.1
26.3 [7.71]
4.2
25.9 [7.59]
4.4
15
[32.2]
Total BTUH [kW]
Power
34.0 [9.96]
3.3
33.4 [9.79]
3.4
32.8 [9.61]
3.5
32.3 [9.47]
3.7
31.8 [9.32]
3.8
31.2 [9.14]
3.9
32.3 [9.47]
4.2
31.7 [9.29]
4.3
31.1 [9.11]
4.5
20
[-6.6]
Total BTUH [kW]
Power
39.1 [11.46]
3.4
38.4 [11.25]
3.5
37.7 [11.05]
3.6
37.5 [10.99]
3.8
36.8 [10.79]
3.9
36.2 [10.61]
4.0
37.4 [10.96]
4.3
36.8 [10.79]
4.4
36.1 [10.58]
4.6
25
[37.8]
Total BTUH [kW]
Power
43.9 [12.87]
3.5
43.2 [12.66]
3.6
42.4 [12.43]
3.7
42.3 [12.40]
3.9
41.5 [12.16]
4.0
40.8 [11.96]
4.1
42.2 [12.37]
4.4
41.5 [12.16]
4.5
40.7 [11.93]
4.7
30
[-1.1]
Total BTUH [kW]
Power
48.4 [14.18]
3.5
47.6 [13.95]
3.7
46.7 [13.69]
3.8
46.8 [13.72]
4.0
46.0 [13.48]
4.1
45.1 [13.22]
4.2
46.7 [13.69]
4.5
45.9 [13.45]
4.6
45.1 [13.22]
4.8
35
[43.3]
Total BTUH [kW]
Power
52.6 [15.42]
3.6
51.7 [15.15]
3.7
50.7 [14.86]
3.9
50.9 [14.92]
4.0
50.1 [14.68]
4.2
49.2 [14.42]
4.3
50.9 [14.92]
4.6
50.0 [14.65]
4.7
49.1 [14.39]
4.8
40
[4.4]
Total BTUH [kW]
Power
56.4 [16.53]
3.7
55.4 [16.24]
3.8
54.5 [15.97]
4.0
54.8 [16.06]
4.1
53.8 [15.77]
4.3
52.9 [15.50]
4.4
54.7 [16.03]
4.6
53.8 [15.77]
4.8
52.8 [15.47]
4.9
18
SYSTEMS PERFORMANCE—RJNA- SERIES

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rheem RJNA Series and is the answer not in the manual?

Rheem RJNA Series Specifications

General IconGeneral
BrandRheem
ModelRJNA Series
CategoryHeat Pump
LanguageEnglish

Related product manuals