Tubing
INSTALLATION
Interconnecting Tubing (cont�)
Figure 5
Insulated liquid and
sucon line
TXV or EEV at indoor
eva
p
orator
Reference Table 2
for elevaon
limitaons
Verify sub-cooling prior
to throlin
g
device
Outdoor Unit Above Indoor Unit
For applications that are considered to have a long
line set with the outdoor unit above the indoor unit
the following is required:
TXV at the indoor unit
Crankcase heater
Start components maybe required depending
upon quality of voltage
Insulated liquid and suction line
Follow the proper line sizing, equivalent length,
charging requirements, and oil level adjustments
spelled out in this document and the outdoor
units I&O
Verify adequate sub-cooling at the ID unit prior
to throttling device