R-410A HEAT PUMP
OUTDOOR UNITS
92-105074-12-00 (01/17)
Printed in USA
[ ] indicates metric conversions.
Do not destroy this manual.
Please read carefully and
keep in a safe place for future
reference by a serviceman.
WARNING
THESE INSTRUCTIONS
ARE INTENDED AS AN AID
TO QUALIFIED, LICENSED
SERVICE PERSONNEL FOR
PROPER INSTALLATION,
ADJUSTMENT, AND
OPERATION OF THIS UNIT.
READ THESE INSTRUCTIONS
THOROUGHLY BEFORE
ATTEMPTING INSTALLATION
OR OPERATION. FAILURE
TO FOLLOW THESE
INSTRUCTIONS MAY
RESULT IN IMPROPER
INSTALLATION,
ADJUSTMENT, SERVICE,
OR MAINTENANCE
POSSIBLY RESULTING IN
FIRE, ELECTRICAL SHOCK,
PROPERTY DAMAGE,
PERSONAL INJURY, OR
DEATH.
INSTALLATION INSTRUCTIONS
(-)P16 (16 SEER) NON-COMMUNICATING
WARNING:
RECOGNIZE THIS SYM-
BOL AS AN INDICATION
OF IMPORTANT SAFETY
INFORMATION
NOTE: Actual unit appearance
may vary.

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Rheem RP1636AJ2NA and is the answer not in the manual?

Rheem RP1636AJ2NA Specifications

General IconGeneral
BrandRheem
ModelRP1636AJ2NA
CategoryHeat Pump
LanguageEnglish

Summary

IMPORTANT SAFETY INFORMATION

General Safety Warnings and Cautions

Covers critical warnings and cautions for safe installation and operation.

INSTALLATION

Choosing an Optimal Location

Guidelines for selecting an optimal installation location considering environment and operational factors.

Tools and Refrigerant

Required Tools and R-410A Refrigerant Specifications

Lists necessary tools and key properties of R-410A refrigerant for installation.

Interconnecting Tubing

Tubing Installation, Connections, and Leak Testing

Best practices for tubing installation, making connections, and performing leak tests.

WIRING

Power Wiring and Grounding Procedures

Guidelines for connecting line voltage power wiring and ensuring proper grounding for safety.

START-UP

Initial Start-Up and Airflow Checks

Procedures for initial unit start-up, including checking system airflow and its importance.

Evacuation and Leak Testing Procedures

Detailed steps for evacuating the system and performing final leak tests.

Refrigerant Charge Adjustment Methods

Covers confirming airflow, setting up measurement devices, and charging by weight.

Gross and Final Refrigerant Charge Adjustment

Methods for adjusting refrigerant charge using pressures and subcooling for optimal performance.

COMPONENTS AND CONTROLS

EVACUATION AND LEAK TESTING

Evacuation and Final Leak Testing Procedures

Comprehensive steps for system evacuation and leak detection.

Refrigerant Charge Verification and Adjustment

Guidance on checking refrigerant charge, setting up equipment, and charging by weight.

Pressure-Based and Subcooling Charge Adjustment

Methods for fine-tuning refrigerant charge using system pressures and subcooling values.

TROUBLESHOOTING

Electrical System Troubleshooting Flow Chart

A flowchart to diagnose electrical issues in the cooling system.

Cooling Mechanical System Troubleshooting Flow Chart

A flowchart to diagnose mechanical problems specific to cooling operation.

START-UP – CHECKING AIRFLOW

DIAGNOSTICS