18
Cooling Performance
1
Continued ->
Gross Cooling Capacity Btu [kW] 24,600 [7.21] 29,800 [8.73] 36,600 [10.72] 36,600 [10.72]
EER/SEER
2
11/13 11.15/13 11/13 11/13
Nominal CFM/ARI Rated CFM [L/s] 800/800 [378/378] 1000/1000 [472/472] 1200/1200 [566/566] 1200/1200 [566/566]
ARI Net Cooling Capacity Btu [kW] 23,600 [6.91] 28,800 [8.44] 35,200 [10.31] 35,200 [10.31]
Net Sensible Capacity Btu [kW] 18,200 [5.33] 22,400 [6.56] 27,000 [7.91] 27,000 [7.91]
Net Latent Capacity Btu [kW] 5,400 [1.58] 6,400 [1.88] 8,200 [2.4] 8,200 [2.4]
Net System Power kW 2.14 2.58 3.2 3.2
Heating Performance (Heat Pumps)
High Temp. Btuh [kW] Rating 23,400 [6.86] 28,800 [8.44] 35,000 [10.26] 35,000 [10.26]
System Power KW / COP 2.07/3.34 2.45/3.44 2.95/3.48 2.95/3.48
Low Temp. Btuh [kW] Rating 13,800 [4.04] 16,200 [4.75] 19,200 [5.63] 19,200 [5.63]
System Power KW / COP 1.91/2.12 2.22/2.14 2.65/2.1 2.65/2.1
HSPF (Btu/Watts-hr) 7.7 7.7 7.7 7.7
Compresso
No./Type 1/Copeland Scroll 1/Copeland Scroll 1/Copeland Scroll 1/Copeland Scroll
Outdoor Sound Rating (dB)
76 76 76 76
Outdoor Coil - Fin Type Louvered Louvered Louvered Louvered
Tube Type Rifled Rifled Rifled Rifled
Tube Size in. [mm] OD 0.375 [9.5] 0.375 [9.5] 0.375 [9.5] 0.375 [9.5]
Face Area sq. ft. [sq. m] 10.44 [0.97] 12.65 [1.18] 12.65 [1.18] 12.65 [1.18]
Rows / FPI [FPcm] 1 / 20 [8] 1 / 20 [8] 1 / 20 [8] 1 / 20 [8]
Refrigerant Control TX Valves TX Valves TX Valves TX Valves
Indoor Coil - Fin Type Louvered Louvered Louvered Louvered
Tube Type Rifled Rifled Rifled Rifled
Tube Size in. [mm] 0.375 [9.5] 0.375 [9.5] 0.375 [9.5] 0.375 [9.5]
Face Area sq. ft. [sq. m] 4.33 [0.4] 4.33 [0.4] 4.33 [0.4] 4.33 [0.4]
Rows / FPI [FPcm] 3 / 13 [5] 3 / 13 [5]
Refrigerant Control TX Valves TX Valves TX Valves TX Valves
Drain Connection No./Size in. [mm] 1/1 [25.4] 1/1 [25.4] 1/1 [25.4] 1/1 [25.4]
Outdoor Fan - Type Propeller Propeller Propeller Propeller
No. Used/Diameter in. [mm] 1/24 [609.6] 1/24 [609.6] 1/24 [609.6] 1/24 [609.6]
Drive Type/No. Speeds Direct/1 Direct/1 Direct/1 Direct/1
CFM [L/s] 3200 [1510] 3200 [1510] 3200 [1510] 3200 [1510]
No. Motors/HP 1 at 1/3 HP 1 at 1/3 HP 1 at 1/3 HP 1 at 1/3 HP
Motor RPM 825 825 825 825
Indoor Fan - Type FC Centrifugal FC Centrifugal FC Centrifugal FC Centrifugal
No. Used/Diameter in. [mm] 1/10x9 [254x228.6] 1/10x9 [254x228.6] 1/10x9 [254x228.6] 1/10x9 [254x228.6]
Drive Type/No. Speeds Direct/2 Direct/2 Direct/2 Direct/2
No. Motors 1 1 1 1
Motor HP 1/4 1/3 1/2 1/2
Motor RPM 1033 1080 1050 1050
Motor Frame Size 48 48 48 48
Filter - Type Field Supplied Field Supplied Field Supplied Field Supplied
Furnished No No No No
(NO.) Size Recommended in. [mm x mm x mm] (1)1x20x16 [25x508x406] (1)1x20x20 [25x508x508] (1)1x24x24 [25x610x610] (1)1x24x24 [25x610x610]
Refrigerant Charge Oz. [g] 90 [2552] 93 [2637] 93 [2637] 93 [2637]
Weights
Net Weight lbs. [kg] 308 [140] 331 [150] 356 [161] 356 [161]
Ship Weight lbs. [kg] 332 [151] 355 [161] 380 [172] 380 [172]
3
4
2 / 15 [5] 3 / 13 [6]
GENERAL DATA - RQNM
NOMINAL SIZES 2-5 TONS [7-17.6 kW]
NOTES:
1. Cooling Performance is rated at 95° F ambient, 80° F entering dry bulb, 67° F entering wet bulb. Gross capacity does not include the effect of fan motor heat. ARI capacity
is net and includes the effect of fan motor heat. Units are suitable for operation in CFM range shown in airflow tables. Units are certified in accordance with the Unitary Air
Conditioner Equipment certification program, which is based on ARI Standard 210/240 or 360.
2. EER and/or SEER are rated at ARI conditions and in accordance with DOE test procedures.
3. Heating Performance is rated at 47° F ambient, 70° F entering dry bulb for High Temp rating and 17° F ambient, 70° F entering dry bulb for Low Temp rating. Performance
ratings do include the effect of fan motor heat.
4. Outdoor Sound Rating shown is tested in accordance with ARI Standard 270.