1 Horsepower per Compressor
2. Amp Draw Per Motor. Multiply Value by Number of Motors to Determine Total Amps.
-B024JK04 -B024JK06 -B024JK08 -B030JK04 -B030JK06 -B030JK08 -B030JK10
U
nit Operating Voltage
R
ange
1
87-253 187-253 187-253 187-253 187-253 187-253 187-253
Minimum Circuit
Ammpacity
21/21 21/21 21/21 24/24 24/24 24/24 24/24
Minimum Overcurrent
Protection Device Size
25/25 25/25 25/25 25/25 25/25 25/25 25/25
Maximum Overcurrent
Protection Device Size
30/30 30/30 30/30 35/35 35/35 35/35 35/35
No. 1 1 1 1 1 1 1
Volts 208/230 208/230 208/230 208/230 208/230 208/230 208/230
Phase 1 1 1 1 1 1 1
H
P 2 1/6 2 1/6 2 1/6 2 2/3 2 2/3 2 2/3 2 2/3
R
PM 3450 3450 3450 3450 3450 3450 3450
A
mps (RLA) 12.8/12.8 12.8/12.8 12.8/12.8 14.1/14.1 14.1/14.1 14.1/14.1 14.1/14.1
Amps (LRA) 58.3/58.3 58.3/58.3 58.3/58.3 73/73 73/73 73/73 73/73
No. 1 1 1 1 1 1 1
Volts 208/230 208/230 208/230 208/230 208/230 208/230 208/230
Phase 1 1 1 1 1 1 1
HP 1/3 1/3 1/3 1/3 1/3 1/3 1/3
Amps (FLA) 1.3 1.3 1.3 1.3 1.3 1.3 1.3
Amps (LRA) 2.3 2.3 2.3 2.3 2.3 2.3 2.3
No. 1111111
Volts 208/230 208/230 208/230 208/230 208/230 208/230 208/230
Phase 1 1 1 1 1 1 1
HP 1/3 1/3 1/3 1/2 1/2 1/2 1/2
Amps (FLA) 2.8 2.8 2.8 4.1 4.1 4.1 4.1
Amps (LRA) 0 0 0 0 0 0 0
ELECTRICAL DATA - RRPL SERIES
Unit InformationCompressor MotorCondenser MotorEvaporator Fan