EasyManua.ls Logo

Rheem RTGH-RH10DV - Page 33

Rheem RTGH-RH10DV
98 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
33
Model
KBP-126H : Fan
CheckPoint
(CircuitBoard)
CN4
Function
The part for supplying the air and gas into the burner required for the combustion.
FailureEvent
① Abnormal noise occurs at the fan.
② Abnormal fan speed(RPM).
③ Poor connection.
E󰘯ects
① Abnormal combustion.
② Abnormal noise occurs.
③ Improper or no operation of water heater.
ErrorCode
Er 41, Er 61
Diagnostic
① Check the clogging of the vents.
② Check status of the connection.
③ Check range of voltage.
Color/WireNumber
[BLDCFAN]
FanStartCoil(white)ⓔ:connector④
RPMSensor(yellow)ⓓ:connector
GND(blue)ⓒ:connector②
VDD(red)ⓑ:connector③
FanEndCoil(black)ⓐ:connector
1.RatedSpeci󰘰cations
-Motortype:DCBRUSHLESSMOTOR
-RatedVoltage:Vs=28V/Vc=DC12V
-WorkingVoltage:Vs=DC28V/Vc=DC12V
-RatedCurrent:2A
-SpeedControl:PWM
Chapter2ComponentsDescription