83
MaincomponentsReplacementInstructions
1.Closethegasshuto󰘯valve.
2.Turnthepowero󰘯.
3.Closeallwatervalve(HotwaterandDHW)
4.Loosenthefastenedscrewsofthecasefront
bracket.
6.Disconnecttheelectricalconnectiontothe
gasvalve.
7.Loosenthenutsasshown.
8.Removethebracket’stwoscrewsandseparate
gasvalvefromthecabinet.
9.Replacethegasvalvewithnewcomponent.
Checktheo-ringsfordamage,ifdamaged,replacewith
newo-rings.
10.Assembleinthereverseorderasthepartwas
removed.
11.Openthegasshuto󰘯valve.
12.Turnthepoweron.
13.Openwatervalves(HotwaterandDHW)
14.Turntheunitonandensureproperoperation.
Chapter5ReplacementInstructions
6.GasValve
NOTE
1.Replaceitwiththenewgasvalve.
2.Checkwireconditionconnectedtogasvalve.
3.Makesurethepackingisinsertedcorrectlywhen
assemblingthenuts.
4.Comparetothemanifoldpressurewithpressure
indicatedattheratingplateafterconnectinggasvalve.
5.Checkforgasleaksafterreinstallingnewgasvalve.