34
Model
MetalFiberPremixBurner
CheckPoint
(CircuitBoard)
N/A
Function
Thepartsupplyingtheheatsourcebymixingandcombustingtheairandgas.
FailureEvent
①Unabletoinitialize/sustaincombustion.
②Sootoccursonthesurfaceofburner.
③Gasleakageoccursfromburner.
E󰘯ects
①Abnormalcombustion.
②Unstable󰘱amegeneration.
③Ignitionfailure.
ErrorCode
N/A
Diagnostic
Checkthedebrisontheburnersurfaceandunstable󰘱ame.
Color/WireNumber
N/A
ThedesignofthePremixBurnersigni󰘰cantlyreducestheamountofemittedcarbonmonoxide(CO),
nitrousoxides(NOx),andotherharmful󰘱uegascomponentsbyregulatingtheair-fuelratiounlike
atypicalBunsenburner.