77
Error Meaning Condition
CascadeCommunication
Abnormality
Whentheunitoperatingisstopped,
errorcode78occurred.
Failureevent
Under
Cascadecommunicationfailure
,
Setting error
,
Back󰘱owoftheExhaustedGas
and
Gas Leak
,
Er78occurred.
Checkpoint
Chapter4Troubleshooting
①CheckQuickConnectcable.
②Checkthesettingsof12:Cnin
InstallerMode
.
③WhenEr40(GasLeak),Er61(Fanerror)orEr67(AGMerror)haveoccurred,Cascade
Communicationerror(Er78)occurstoprotect‘BackFlow’oftheexhaustedgas.
IncaseofEr45(WaterLeak),bothunitsshutdowntominimizethepropertydamageduetoan
internalleak.
④Checkthatoneoftheaboveerrorsisoccurred.
QuickConnectcable