EasyManua.ls Logo

Rheem RTGH-RH10DV - Chapter 5 Replacement Instructions; Circuit Board

Rheem RTGH-RH10DV
98 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
79
1.Closethegasshuto󰘯valveandwatervalve.
2.Turnthepoweron.
3.Enter'InstallerMode','StatusMode'fromcontrol
panel.(Seepage44,45)
4.Onapieceofpaper,writedownthefactorysettingsin
the'InstallerMode'for4:FH,5:FL,'StatusMode'J:AG.
ThesenumbersMUSTberecordedbeforetheoldcircuit
boardisremoved,thevalvesarespeci󰘰ctotheunit.
5.Turnthepowero󰘯waterheater.(Usethemanual
switch)
6.UnplugconnectorsonCircuitboard.
7.LoosentwoscrewstoremoveCircuitboard.
8.Removethecircuitboardandreplacewithnewcircuitboard.
9.Reconnectallwireconnectionstothenewcircuitboard.
10.Verifythedipswitchsettingsarecorrectonthe
newcircuitboard.(Seenormal󰘰rein󰘰gurebelow)
11.Openthegasshuto󰘯valve.
12.Openallwatervalves.
13.Turnthepoweron.(Usethemanualswitch)
14.Enter’InstallerMode’,'StatusMode'fromcontrol
panel.
15.Setthevaluesfor 4:FH,5:FL,J:AG.
(ThesearethenumbersyouwrotedowninStep4)
16.Savethevaluesfor4:FH,5:FL,J:AG.
17.Turntheunitonandensureproperoperation.
18.Testoperation.
Ifcarbondioxideandmanifoldpressurevalues
arematchedwithTable1inthelow󰘰recombustion,
switchdipswitchfromlowtohigh󰘰reandcheck
carbondioxideandmanifoldpressurevalues.Ifthe
valuesarematchedwithTable1,shuto󰘯theunitand
closethegasvalve.Thendisconnectthehosethatis
connectedtothemanifoldpressureport,thentighten
thescrewforthemanifoldpressureport,andreturn
thedipswitchbacktonormalcondition.Finally,close
thefrontcover.
NOTE
Whenassembleconnector,checkwiringcolor
andlocationstoavoidanymistakes.
Dip Switch State
5 Gas Type NG : ON LP:OFF
6 High Fire 6: ON 7: OFF
7 Low Fire 6: OFF 7: ON
6, 7 Normal Fire 6: OFF 7: OFF
Manifold
pressure
(±0.01˝)
'LP'type 'NG'type
2˝VENT 3˝VENT 2˝VENT 3˝VENT
199,000
Btu/hr
High
󰘰re
-0.3" W.C -0.25" W.C -0.38" W.C -0.33" W.C
Low
󰘰re
-0.02" W.C -0.02" W.C -0.07" W.C -0.07" W.C
180,000
Btu/hr
High
󰘰re
-0.28
" W.C
-0.23
" W.C
-0.36
" W.C -0.31" W.C
Low
󰘰re
-0.02" W.C -0.02" W.C -0.07" W.C -0.07" W.C
Table 1
MaincomponentsReplacementInstructions
Chapter5ReplacementInstructions
1.CircuitBoard
Fire
199,000Btu
(LP)
180,000Btu
(LP)
199,000Btu
(NG)
180,000Btu
(NG)
High
Fire
Low
Fire
Normal
Fire