EasyManua.ls Logo

Rheem RTGH-RH11DV - Chapter 4: Troubleshooting - Exhaust Temperature Sensing; Er:35 Exhaust Thermistor Error

Rheem RTGH-RH11DV
98 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
63
Errorcode Meaning Condition
ExhaustThermistorOpenor
ShortCircuit
(Automaticrestore)
WhennoresponseatExhaust
Thermistor,errorcode35will
appear.
Failureevent
When ExhaustThermistor’swiringlinelocatedatExhaustisdisconnected.
Checkpoint
Chapter4Troubleshooting
①VerifythattheExhaustThermistorisproperlysecured
intheexhaustconnection.Verifyproperconnectionof
theExhaustThermistor'swiringtothecircuitboard.
(CN7:White⑤,Blue⑫)
②MeasureresistanceacrosstheExhaust
Thermistorwithamulti-meter.Ifthemulti-meter
displays0Ω(shortcircuit),replacetheExhaust
Thermistor.
Exhaust(White/Blue)

Other manuals for Rheem RTGH-RH11DV

Related product manuals