EasyManua.ls Logo

Rheem RTGH-RH11DV - Chapter 4: Troubleshooting - Cascade Systems; Er:78 Cascade Communication Abnormality

Rheem RTGH-RH11DV
98 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
77
Error Meaning Condition
CascadeCommunication
Abnormality
Whentheunitoperatingisstopped,
errorcode78occurred.
Failureevent
Under
Cascadecommunicationfailure
,
Setting error
,
Back󰘱owoftheExhaustedGas
and
Gas Leak
,
Er78occurred.
Checkpoint
Chapter4Troubleshooting
①CheckQuickConnectcable.
②Checkthesettingsof12:Cnin
InstallerMode
.
③WhenEr40(GasLeak),Er61(Fanerror)orEr67(AGMerror)haveoccurred,Cascade
Communicationerror(Er78)occurstoprotect‘BackFlow’oftheexhaustedgas.
IncaseofEr45(WaterLeak),bothunitsshutdowntominimizethepropertydamageduetoan
internalleak.
④Checkthatoneoftheaboveerrorsisoccurred.
QuickConnectcable

Other manuals for Rheem RTGH-RH11DV

Related product manuals