Rheem RTGH-RH11DV - Chapter 4: Troubleshooting - Exhaust Temperature; Er:94 Exhaust Temperature Exceeds Limit

Rheem RTGH-RH11DV
98 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
78
Errorcode Meaning Condition
Exhausttemperatureexceeds
selectedcuto󰘯temperature.
(Manualrestore)
OverheatingExhaustThermistor
(Thewaterheatershutsdown
whentheexhausttemperature
exceeds149°F(65°C).)
Failureevent
Itoccurswhenexhaustgasemissionisfaultyduetoexhaust󰘱ueblockage.
Whenexcessiveamountofgasin󰘱owsduetohighersetofdipswitchthanitshotwaterheatercapacity,
exhaustgastemperaturewillincreasemorethanexcesstemperature.Exhaustgastemperaturemaybe
highduetoheatexchanger'smalfunction.
Checkpoint
③Checkforanyobstructionsintheventpipe.
①Turno󰘯thewaterheaterforatleast30minutes,andthenrestartit.
②CheckExhaustThermistor’swiringconnectedatexhaust
ductisdisconnected.Andcheckcircuitboardssocket.
(CN7:White⑤,Blue⑫)