EasyManua.ls Logo

RHOSS DIVA-I User Manual

RHOSS DIVA-I
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
H57997
Italiano English Français Deutsch Español
ISTRUZIONI PER L’USO
INSTRUCTIONS FOR USE
MODE D’EMPLOI
GEBRAUCHSANWEISUNG
INSTRUCCIONES DE USO
Ventilconvettore
Fan coil
Ventilo convecteur
Klimakonvektoren
Fan coil
DIVA-I 30÷110

Questions and Answers:

RHOSS DIVA-I Specifications

General IconGeneral
BrandRHOSS
ModelDIVA-I
CategoryAir Conditioner
LanguageEnglish

Summary

Purpose and Initial Instructions

Read Manual Before Installation

Carefully read this manual before proceeding with the appliance installation.

Appliance Identification

Identification Plate and Packaging

Details the identification plate on the unit and its packaging information.

Weights, Dimensions, and Delivery Notes

Weights and Dimensions Table

Provides weight and dimension data for different appliance models.

General Notes on Delivery

Details appliance parts and packaging contents upon delivery.

General Warnings and Safety Information

Read Manual Carefully and Observe Sound Pressure Limits

Emphasizes careful reading of the manual for safety and notes the sound pressure level limit (< 70 dB(A)).

Important Work Areas and Personnel Requirements

Covers handling, installation, maintenance, electrical, and refrigeration work requiring trained personnel.

Scope, Qualifications, and Safety Rules

Manual Coverage Areas

Defines the manual's coverage areas and requirements for qualified personnel.

Personnel Responsibilities and Safety

Details qualified personnel requirements, manufacturer liability, and booklet integration.

Fundamental Safety Rules

General Installation Safety

Covers safety regulations, accident prevention, and relevant codes for installation and repairs.

Skilled Worker and Personnel Requirements

Ensures skilled workers understand their tasks and can identify/avoid risks.

Safety for Transport and Maintenance Personnel

Specifies training and instruction requirements for personnel involved in transport, commissioning, and maintenance.

Installation Precautions and Handling Safety

General Installation Warnings

Includes warnings on safety switch, earthing, environmental conditions, frost, and general handling.

Safe Handling and Lifting Practices

Provides guidelines for safe unit handling, lifting tackle usage, and avoiding hazards.

Safety Warnings and Maintenance Procedures

General Safety Recommendations and Operating Limits

Covers safety labels, packaging disposal, operating pressure, and air intake/discharge guidelines.

Maintenance Safety and Electrical Hazards

Emphasizes power disconnection, capacitor discharge, valve closure, and electrical safety during maintenance.

Usage Guidelines and Operating Limits

Usage Restrictions and Environmental Considerations

Outlines restrictions on flammable gases, foreign objects, wet conditions, water spray, and cold climate procedures.

Technical Specifications

Fan Coil and Heat Exchanger Specifications

Details temperature, pressure, voltage, and consumption for fan coil and heat exchanger.

Valve and Other Technical Data

Provides valve specifications and refers to other sections for additional technical data.

Installation Procedures

Installation Requirements and Preparations

Covers adherence to standards, hydraulic/electrical connections, ceiling preparation, and pipe/cable installation.

Location and Mounting Guidelines

Specifies installation within suspended ceilings, air circulation, and minimum space requirements.

Environmental Conditions and Air Handling

Air Temperature, Humidity, and Handling Parameters

Defines acceptable air temperature range (6-40°C) and relative humidity (15-75%) for unit operation.

Air Ducting and Flow Considerations

Details optional air pipe adapters and limits on treated air flow for system design.

Mechanical Installation Guide

Ceiling Installation and Airflow Direction

Addresses air stratification and correct positioning of outlet grills for downward airflow.

Cassette Fixing and Procedure

Explains fixing the unit with threaded rods and outlines the step-by-step installation procedure.

Air Outlet Connections and Ducting

Ducting Requirements and Airflow Characteristics

Covers air outlet connections, airflow dependency on outlet count, and airflow charts.

Air Duct Insulation and Final Connections

Mandates thermal insulation for air ducts and instructs to complete hydraulic and electrical connections.

Water Connections and Fluid Handling

Hydraulic Connection and Fluid Specifications

Details connection requirements, fluid type, temperature, pressure, and valve usage.

Condensate Management and Safety Warnings

Advises on condensate prevention during summer/inactive periods and proper drain hose installation.

Condensate Management Components

Condensate Tray Functionality

Describes the condensate tray's role in collecting condensation from heat exchanger and control valve connections.

Valve Connections and Specifications

Valve Connection References and Types

Indicates valve connection diagrams and details two-way/three-way valve information.

Valve Performance and Flow Control

Provides valve specifications, pressure drop data, sealing methods, and notes on maximum pressure drop for flow control.

Electrical Connections and Safety Precautions

Connection Standards and Power Supply Requirements

Follows national laws for electrical connections; verifies voltage and system capacity.

Controller Signals, Grounding, and Disconnection

Details controller signal origin, placement, earthing, and mandatory power disconnection before access.

Electrical Connection Guidance

Wiring Diagrams and Component Functions

Advises following wiring diagrams and explains electrical components like thermal protection and pump control.

Leakage Current and Compliance

Addresses leakage current considerations in design and compliance with CEI-EN 60335 standards.

Controller Operating Limits and Setup

Controller Placement and Specification Requirements

Stresses correct controller placement inside the shunt panel and specifies required characteristics.

Connecting Multiple Units with Single Controller

Inverter Unit Signal Requirements for Centralized Control

Explains that each INVERTER unit needs an internal 0-10Vdc signal, not to be shared.

Electric Resistance Heating System

Resistance Heating Configuration and Safety Features

Details the 2-pipe resistance configuration, its management, and safety features.

Electric Resistance Specifications and Connections

Lists power, voltage, current, fuse, and required cable/switch specifications.

Safety Warnings and Thermostat Management

Pre-Activation Checks and Environmental Considerations

Guides on fan check, air louvers, temperature probes with heaters, and environmental limits.

Safety Thermostat Operation and Reset

Explains the function of safety thermostats (manual/automatic reset) and procedures for identifying causes and resetting.

Operating Limits for Electric Coil Units

Specifies the maximum ambient temperature for heating mode (25°C) for units with electric coils.

Installation with Installer-Provided Valves

Installer Responsibilities for Valves and Connections

Follow manufacturer instructions for valve installation and refer to drawings for Cassette connections.

Condensate Prevention and Valve Wiring Safety

Advises on condensate prevention in cold water systems and details critical valve connection precautions and risks.

Valve Wiring Diagrams and Safety Precautions

Critical Valve Connection Precautions

Covers cable routing, power failure operation, overflow risk, closing/opening timing, and leak testing.

Standard Controls

KTVDI Electronic Control Panel

5-button panel with LCD for manual/automatic temperature control, wall-mountable.

KPCM Electronic Control Panel

11-button electronic panel with LCD for manual/automatic regulation, wall-mounted.

KTCM Infrared Remote Control

Remote control with LCD for manual/automatic regulation, includes wall bracket.

KICM Recessed Panel Control

Recessed panel with LCD for electronic Fan Coil CMS control, for 3-module boxes.

Advanced Controls

KCM12-KCM14 Configurable Card

Master/Slave card for manual/automatic adjustment, with MVRI module for fan and valves.

Serial Interfaces for Advanced Controls

KISI CAN-bus Serial Interface

CAN-bus interface for iDRHOSS system, essential for network connection and unit addressing.

KRS485 RS485 Serial Interface

RS485 interface for building automation and supervision systems, associated with KCMS board.

Serial Converters for System Integration

KUSB RS485/USB Converter

Converter for supervisory systems, linking to KRS485 modules for centralized management.

KGTW-BAC Gateway

Gateway supporting RS485/BACnet, up to 64 devices.

KGTW-LON Gateway

Gateway supporting RS485/FTT10-LonWorks, up to 64 devices.

Cleaning, Maintenance, and Spare Parts

Maintenance Personnel and Safety Precautions

Only trained personnel should service equipment; disconnect power before cleaning/maintenance.

Component Maintenance Guidelines

Fan and heat exchanger coil require no ordinary maintenance; filter maintenance detailed.

Filter Maintenance Procedures

Details filter removal, cleaning methods, replacement, and grille reinstallation.

Spare Parts Ordering Information

Specify appliance model and component description when ordering spare parts.

Troubleshooting and Maintenance

Troubleshooting Common Malfunctions

Addresses fan issues, airflow, noise, heating/cooling deficiencies, and water leaks with causes and remedies.

Routine Maintenance Procedures

Covers general maintenance precautions, filter cleaning, replacement, and grille reinstallation.

Malfunctions and Solutions Guide

Fan Operation and Airflow Problems

Troubleshooting steps for fan not starting, insufficient airflow, noisy operation, and related causes.

Heating, Cooling, and Leakage Issues

Addresses unit performance problems in heating/cooling modes, leaks, and temperature fluctuations with solutions.

Related product manuals