SERVICE CALL CONDITIONS
SM 4-49 B234/B235/B236/D101/D102/D103
Trouble-
shooting
Pre-bind jogger clamp HP error 792-9 D
Not detected at HP after the time
prescribed to arrive at the HP had
elapsed (more than 400 ms) (1st
detection, jam, 2nd detection, SC
error)
-or-
Detected at HP after the time
prescribed to leave the HP had
elapsed (more than 400 ms) (1st
detection, jam, 2nd detection, SC
error)
• Spine clamp motor (M605) connector
loose, broken, defective
• Motor defective
• Motor overload
• Clamp HP sensor (S603) connector
loose, broken, defective
• Sensor defective
Binder unit runout error
792-10 D
Not detected at HP after the time
prescribed to arrive at the HP had
elapsed (more than 400 ms) (1st
detection, jam, 2nd detection, SC
error)
-or-
Detected at HP after the time
prescribed to leave the HP had
elapsed (more than 400 ms) (1st
detection, jam, 2nd detection, SC
error)
• Runout press roller motor (M610)
connector loose, broken, defective
• Motor defective
• Motor overload
• Runout roller HP sensor (S614)
connector loose, broken, defective
• Sensor defective
Clamp thickness error 792-11 D
50-sheet detection sensor (S606) went OFF
during pre-bind jogging when a 100-sheet
thickness was detected. (1st detection jam,
2nd detection SC error)
-or-
50-sheet detection sensor went OFF at
initialization when the clamp moved to the
open position.
• 50-sheet detection sensor
(S606) connector loose,
broken, defective
• Sensor defective
Alignment pin error
792-12 D
Not detected at HP after the time
prescribed to arrive at the HP had
elapsed (more than 400 ms) (1st
detection, jam, 2nd detection, SC
error)
-or-
Detected at HP after the time
prescribed to leave the HP had
elapsed (more than 400 ms) (1st
detection, jam, 2nd detection, SC
error)
• Alignment pin motor (M602)
connector loose, broken, defective
• Motor overload
• Motor defective
• Alignment pin HP sensor (S604)
connector loose, broken, defective
• Sensor defective