Main SP Tables-1
D146/D147/D148/D149/D150 2-16 System Maintenance Section
Do not change. Difference value from reload permission target value: cold BW:
edge
018
Temp.:Delta:Cold:BW1/2:Press *ENG
[0 to 200 /
D146:110,
D147:110,
D148:110,
D149:90,
D150:90 /
1deg/step]
Do not change. Difference value from reload permission target value: cold BW:
pressure
019
Forced Reload Time:Cold:BW1/2
*ENG
[0.0 to 100.0 /
D146:42,
D147:42,
D148:50,
D149:61,
D150:61 /
0.1sec/step]
Do not change. Force reload time when cold BW
101
Reload Target Temp.:Center:Energy Saving
*ENG
[0 to 200 / D146:
115, D147: 115,
D148: 125, D149:
127, D150: 127 /
1deg/step]
Do not change. Reload permission target temperature: center BW2
102
Reload Target Temp.:Press:Energy Saving *ENG
[0 to 200 /
D146:120,
D147:120,
D148:120,
D149:100,
D150:100 /
1deg/step]
Do not change. Reload permission target temperature: pressure BW2