Main SP Tables-1
System Maintenance Section 2-19 D146/D147/D148/D149/D150
SP Mode Tables
204
Forced Reload Time:Cold:FIN-less/ADF-less
*ENG
[0.0 to 100.0 /
D146:4.9,
D147:4.9,
D148:5.0,
D149:6.1,
D150:6.1 /
0.1sec/step]
Do not change. Reload permission force reload time: cold: No FIN/No ADF
211
Temp:Delta:Cold:Center:FIN-less/ADF-attached *ENG
[0 to 200 /
D146:31,
D147:31,
D148:33,
D149:32,
D150:32 /
1deg/step]
Do not change. Reload permission temperature: difference: cold center: No
FIN/With ADF
212
Temp.:Delta:Cold:End:FIN-less/ADF-attached *ENG
[0 to 200 /
D146:31,
D147:31,
D148:33,
D149:32,
D150:32 /
1deg/step]
Do not change. Reload permission temperature: difference: cold edge: No
FIN/With ADF
213
Temp.:Delta:Cold:Press:FIN-less/ADF-attached *ENG
[0 to 200 /
D146:110,
D147:110,
D148:110,
D149:90,
D150:90 /
1deg/step]
Do not change. Reload permission temperature: difference: cold pressure: No
FIN/With ADF