Main SP Tables-1
System Maintenance Section 2-123 D146/D147/D148/D149/D150
001 Judging Method Change *ENG
[0 to 3 / 3 / 1/step]
0: All Off
1: CPM Down:On
2: Job End Rotation:On
3: All On
002 Output Correction:MBD *ENG [80 to 120 / 100 / 1%/step]
003 Power Rate Control:MBD *ENG
[0 to 100 / NA, TW: 89, EU, AS,
CHN, KOR: 51 / 1%/step]
004 Press Reference Temp.:MBD *ENG [0 to 250 / 85 / 1deg/step]
005 Calculation Cycle:MBD *ENG
[1 to 5 / NA, TW:1 , EU, AS, CHN,
KOR: 2 / 1sec/step]
006 Correction Coefficient 1:MBD *ENG [0 to 99 / 14 / 1/step]
007 Correction Coefficient 2:MBD *ENG [0 to 99 / 83 / 1/step]
008 Correction Coefficient 3:MBD *ENG [0 to 99 / 8 / 1/step]
009 Correction Coefficient 4:MBD *ENG [0 to 99 / 28 / 1/step]
010 Correction Coefficient 5:MBD *ENG [0 to 99 / 83 / 1/step]
011 Correction Coefficient 6:MBD *ENG [0 to 99 / 17 / 1/step]
021 Judgement Temp:MBD *ENG [0 to 500 / 270 / 1deg/step]
022 Cooling Time Set:MBD *ENG [0 to 99 / 10 / 1sec/step]
031 1st CPM Down Temp.:MBD *ENG [0 to 500 / 320 / 1deg/step]
032 2nd CPM Down Temp.:MBD *ENG [0 to 500 / 330 / 1deg/step]
033 3rd CPM Down Temp.:MBD *ENG [0 to 500 / 350 / 1deg/step]
034 1st CPM:MBD *ENG [0 to 100 / 85 / 1%/step]
035 2nd CPM:MBD *ENG [0 to 100 / 75 / 1%/step]
036 3rd CPM:MBD *ENG [0 to 100 / 50 / 1%/step]