1. Clean the covers.
Perform the following SP Modes in the following
order.
1. SP2-214 TD Sensor Initial Setting
2. SP3-001 ID Sensor Initial Setting
3. SP3-112 Forced VR Detection
4. * SP4-001 Exposure Lamp Voltage Adj.
5. SP4-201 Auto ADS Gain Adj.
6. * SP3-105 Forced VL Detection
*: Perform these SP modes only if the exposure
lamp has been replaced.
Make a copy of an OS-A3 test chart at manual
image density level 4.
11. Exterior (every 100
or 120 k)
12. Copy Process SP
Mode Settings
13. Make a Copy