10.3.2 Highest ID Level Bias (Manual ID Level 7) Adjustment (SP2-201-002)
When: If a customer requests a lighter or darker copy image
density at manual image density level 7.
Purpose: To meet any customer’s requests about the image
density at manual ID level 7.
How: SP2-201-002 changes the development bias voltage
for images at manual ID level 7.
SP2-201-002: Highlight Bias
Setting Density
Development Bias
Correction Voltage
1 Normal –40V
2 Dark
± 0V
3 Lighter –80V
4 Lightest –120V
1. Enter SP2-201-002.
2. Change the setting displayed in the reduce/enlarge indicator with the number
keys. Determine the new setting from the above table.
3. Leave SP2-201-002.