SP Modes - Symptom Troubleshooting - 1/3
SP 1103: Fusing idling enable/disable
Enable if fusing on the first two copies is incomplete
SP 1108: Fusing temperature control cycle
Increase if the user complains about flickering room lights.
However, fusing lamp errors may not be detected.
SP 1903: Re-energizes the feed clutch
Increase the value if jams occur when feed restarts after
registration]
SP 2213: Number of copies after near-end
If the user makes a lot of copies with a high proportion of
black, reduce this setting.
Also you can try increasing the value of SP 2922 and/or SP
2925
.