001
SBU_ID ENG [0x00 to 0xFF / 0 / 1/step]
Displays SUB ID.
In occasions that SUBs ID is not normal cause to a part installed wrong or SUB malfunction,
A cause flag will be set to SP4-647-001 and will become SC144-00.
002
SCAT _F_ID ENG [0x00 to 0xFF / 0 / 1/step]
Displays SBU (SCAT: F Side) ID.
In occasions that SUBs ID is not normal cause to a part installed wrong or SUB malfunction,
A cause flag will be set to SP4-647-001 and will become SC144-00.
003
SCAT_L_ID ENG [0x00 to 0xFF / 0 / 1/step]
Displays SBU (SCAT: L side) ID.
In occasions that SUBs ID is not normal cause to a part installed wrong or SUB malfunction,
A cause flag will be set to SP4-647-001 and will become SC144-00.
4609 [Gray Balance Set: R]
001
Book Scan *ENG [-384 to 255 / -100 / 1digit/step]
Display/Saves Gray Balance Adjustment value (RED) of Scanners surface (Book)
Adjusted Value during the warranty process of scan unit is saved.
002
DF Scan *ENG [-384 to 255 / -100 / 1digit/step]
Display/Saves Gray Balance Adjustment value (RED) of Scanners surface (ADF)
Adjusted Value during the warranty process of scan unit is saved.
• With DF Density Adjustment value: SP4-688-002, GrayBalance Adjustment value
correction is available for when DF reading.
• (Density Difference correction of Book Scan and DF Surface Scan).
4610 [Gray Balance Set: G]
001
Book Scan *ENG [-384 to 255 / -100 / 1digit/step]
Display/Saves Gray Balance Adjustment value (GREEN) of Scanners surface (Book)
Adjusted Value during the warranty process of scan unit is saved.
2. Main SP Tables-4