053 Feed Counter:M *ENG
[0.0 to 99999999.0 / 0.0 / 0.1mg/
step]
054 Feed Counter:Y *ENG
[0.0 to 99999999.0 / 0.0 / 0.1mg/
step]
3110 [TNE Detect(Lvl1) :Set]
001
ON/OFF *ENG [0 to 1 / 0 / 1/step]
Sets whether to display Toner Near End (Level 1) on the operation panel.
011
Disp Timing:K *ENG [10 to 100 / 10 / 1%/step]
Sets whether to display Toner Near End (Level 1) on the operation panel at which
percentage of Toner Remains.
012
Disp Timing:C *ENG [10 to 100 / 10 / 1%/step]
Sets whether to display Toner Near End (Level 1) on the operation panel at which
percentage of Toner Remains.
013
Disp Timing:M *ENG [10 to 100 / 10 / 1%/step]
Sets whether to display Toner Near End (Level 1) on the operation panel at which
percentage of Toner Remains.
014
Disp Timing:Y *ENG [10 to 100 / 10 / 1%/step]
Sets whether to display Toner Near End (Level 1) on the operation panel at which
percentage of Toner Remains.
3120 [TNE Detect(Lvl2) :Set]
001
Set Cnt *ENG [0 to 255 / 30 / 1count/step]
Sets the timing when Toner Near End (Level 2) is set after how many times Toner End
Sensor continuously detects Toner Empty.
011
Cnt:K *ENG [0 to 255 / 0 / 1count/step]
Displays how many times Toner End Sensor (K) continuously detects Toner Empty.
012
Cnt:C *ENG [0 to 255 / 0 / 1count/step]
Displays how many times Toner End Sensor (C) continuously detects Toner Empty.
SP3-XXX (Process)
17