5517 [Get Machine Information]
021
GeCustomPprInfo:RetryInterval *CTL [10 to 255 / 10 / 1min/step]
When ID info collect is interrupt, retries during the time between receving Request for
obtaining custom paper info, to value set with this setting.
031
Get SMC Info Retry Internal *CTL [10 to 255 / 10 / 1min/step]
When SMC info collect is interrupt, retries during the time between receving Request for
obtaining SMC info, to value set with this setting.
5610 [Base Gamma Ctrl Pt: Execute]
004
Factory Setting *ENG [0 or 1 / 0 / 1/step]
Recalls the factory settings.
005
Restore *ENG [0 or 1 / 0 / 1/step]
Overwrites the current values onto the factory settings.
006
Restore *ENG [0 or 1 / 0 / 1/step]
Recalls the previous settings.
5611 [Toner Color in 2C]
001
B-C *ENG
[0 to 128 / 100 / 1 /step]
128: Darkest density
Adjusts the output color (C component) ranging from 0 (%) to 128 (%) when Standard
Color (Blue) is set in Single Color (No correction).
002
B-M *ENG
[0 to 128 / 100 / 1 /step]
128: Darkest density
Adjusts the output color (M component) ranging from 0 (%) to 128 (%) when Standard
Color (Blue) is set in Single Color (No correction).
003
G-C *ENG
[0 to 128 / 100 / 1 /step]
128: Darkest density
Adjusts the output color (C component) ranging from 0 (%) to 128 (%) when Standard
Color (Green) is set in Single Color (No correction).