Technical Bulletin PAGE: 5/13
Reissued: 17-Jan-17
Model: Vacuum Feed LCIT RT5100
How to replace the Pulley Cover (p/n: D7772784)
1. Replace the pulley cover [A] with the new type cover.
NOTE: The pulley used to stick out from the pulley cover with the old type cover, so the
new type cover has been made wider [B] (37.4mm 42.4mm) and covers the
edge of the pulley as shown in [C].
The pulley cover is installed at
front and rear sides of the
paper tray respectively.
(1 screw for each)