GENERAL REMARKS
10
PARAMETERS UM
CONDEXA
METHANE GAS (G20) LIQUID PROPANE GAS (G31)
Lower Wobbe index (at 15°C-1013 mbar) MJ/m³S 45,67 70,69
Net caloric value MJ/m³S 34,02 88
Nominal supply pressure mbar (mm H2O) 20 (203,9) 37 (377,3)
Minimum supply pressure mbar (mm H2O) 10 (102,0) -
HPR 35
Burner: diameter/length
mm
70/160 70/160
Diaphragm: number of holes - hole diameter
n° - mm
1 - 6,5 1 - 5,1
Maximum gas ow rate (heating)
Sm³/h
3,69 -
kg/h
- 2,71
Maximum gas ow rate (DHW)
Sm³/h
3,69 -
kg/h
- 2,71
Minimum gas ow rate (heating)
Sm³/h
0,55 -
kg/h
- 0,40
Minimum gas ow rate (DHW)
Sm³/h
0,55 -
kg/h
- 0,40
Number of fan rotations (slow ignition)
rpm
4.000 4.000
Maximum number of fan rotations (heating)
rpm
7.300 7.100
Minimum number of fan rotations (heating)
rpm
1.750 1.650
HPR 45
Burner: diameter/length
mm
70/160 70/160
Diaphragm: number of holes - hole diameter
n° - mm
1 - 6,5 1 - 5,1
Maximum gas ow rate (heating)
Sm³/h
4,76 -
kg/h
- 3,49
Maximum gas ow rate (DHW)
Sm³/h
4,76 -
kg/h
- 3,49
Minimum gas ow rate (heating)
Sm³/h
0,55 -
kg/h
- 0,40
Minimum gas ow rate (DHW)
Sm³/h
0,55 -
kg/h
- 0,40
Number of fan rotations (slow ignition)
rpm
4.000 4.000
Maximum number of fan rotations (heating)
rpm
9.100 8.900
Minimum number of fan rotations (heating)
rpm
1.750 1.650
HPR 55
Burner: diameter/length
mm
70/150 70/150
Diaphragm: number of holes - hole diameter
n° - mm
2 - 5,6 (up) - 5,3 (down) 2 - 4,1 (up) - 4,1 (down)
Maximum gas ow rate (heating)
Sm³/h
5,82 -
kg/h
- 4,27
Maximum gas ow rate (DHW)
Sm³/h
5,82 -
kg/h
- 4,27
Minimum gas ow rate (heating)
Sm³/h
0,87 -
kg/h
- 0,64
Minimum gas ow rate (DHW)
Sm³/h
0,87 -
kg/h
- 0,64
Number of fan rotations (slow ignition)
rpm
3.000 2.400
Maximum number of fan rotations (heating)
rpm
6.800 6.300
Minimum number of fan rotations (heating)
rpm
1.850 1.750
HPR 70
Burner: diameter/length
mm
70/150 70/150
Diaphragm: number of holes - hole diameter
n° - mm
2 - 5,6 (up) - 5,3 (down) 2 - 4,1 (up) - 4,1 (down)
Maximum gas ow rate (heating)
Sm³/h
7,40 -
kg/h
- 5,44
Maximum gas ow rate (DHW)
Sm³/h
7,40 -
kg/h
- 5,44
Minimum gas ow rate (heating)
Sm³/h
0,87 -
kg/h
- 0,64
Minimum gas ow rate (DHW)
Sm³/h
0,87 -
kg/h
- 0,64
Number of fan rotations (slow ignition)
rpm
3.000 2.400
Maximum number of fan rotations (heating)
rpm
8.200 7.800
Minimum number of fan rotations (heating)
rpm
1.850 1.750

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Riello CONDEXA HPR Series and is the answer not in the manual?

Riello CONDEXA HPR Series Specifications

General IconGeneral
BrandRiello
ModelCONDEXA HPR Series
CategoryWater Heater
LanguageEnglish

Related product manuals