GENERAL REMARKS
10
PARAMETERS UM
CONDEXA
METHANE GAS (G20) LIQUID PROPANE GAS (G31)
Lower Wobbe index (at 15°C-1013 mbar) MJ/m³S 45,67 70,69
Net caloric value MJ/m³S 34,02 88
Nominal supply pressure mbar (mm H2O) 20 (203,9) 37 (377,3)
Minimum supply pressure mbar (mm H2O) 10 (102,0) -
HPR 35
Burner: diameter/length
mm
70/160 70/160
Diaphragm: number of holes - hole diameter
n° - mm
1 - 6,5 1 - 5,1
Maximum gas ow rate (heating)
Sm³/h
3,69 -
kg/h
- 2,71
Maximum gas ow rate (DHW)
Sm³/h
3,69 -
kg/h
- 2,71
Minimum gas ow rate (heating)
Sm³/h
0,55 -
kg/h
- 0,40
Minimum gas ow rate (DHW)
Sm³/h
0,55 -
kg/h
- 0,40
Number of fan rotations (slow ignition)
rpm
4.000 4.000
Maximum number of fan rotations (heating)
rpm
7.300 7.100
Minimum number of fan rotations (heating)
rpm
1.750 1.650
HPR 45
Burner: diameter/length
mm
70/160 70/160
Diaphragm: number of holes - hole diameter
n° - mm
1 - 6,5 1 - 5,1
Maximum gas ow rate (heating)
Sm³/h
4,76 -
kg/h
- 3,49
Maximum gas ow rate (DHW)
Sm³/h
4,76 -
kg/h
- 3,49
Minimum gas ow rate (heating)
Sm³/h
0,55 -
kg/h
- 0,40
Minimum gas ow rate (DHW)
Sm³/h
0,55 -
kg/h
- 0,40
Number of fan rotations (slow ignition)
rpm
4.000 4.000
Maximum number of fan rotations (heating)
rpm
9.100 8.900
Minimum number of fan rotations (heating)
rpm
1.750 1.650
HPR 55
Burner: diameter/length
mm
70/150 70/150
Diaphragm: number of holes - hole diameter
n° - mm
2 - 5,6 (up) - 5,3 (down) 2 - 4,1 (up) - 4,1 (down)
Maximum gas ow rate (heating)
Sm³/h
5,82 -
kg/h
- 4,27
Maximum gas ow rate (DHW)
Sm³/h
5,82 -
kg/h
- 4,27
Minimum gas ow rate (heating)
Sm³/h
0,87 -
kg/h
- 0,64
Minimum gas ow rate (DHW)
Sm³/h
0,87 -
kg/h
- 0,64
Number of fan rotations (slow ignition)
rpm
3.000 2.400
Maximum number of fan rotations (heating)
rpm
6.800 6.300
Minimum number of fan rotations (heating)
rpm
1.850 1.750
HPR 70
Burner: diameter/length
mm
70/150 70/150
Diaphragm: number of holes - hole diameter
n° - mm
2 - 5,6 (up) - 5,3 (down) 2 - 4,1 (up) - 4,1 (down)
Maximum gas ow rate (heating)
Sm³/h
7,40 -
kg/h
- 5,44
Maximum gas ow rate (DHW)
Sm³/h
7,40 -
kg/h
- 5,44
Minimum gas ow rate (heating)
Sm³/h
0,87 -
kg/h
- 0,64
Minimum gas ow rate (DHW)
Sm³/h
0,87 -
kg/h
- 0,64
Number of fan rotations (slow ignition)
rpm
3.000 2.400
Maximum number of fan rotations (heating)
rpm
8.200 7.800
Minimum number of fan rotations (heating)
rpm
1.850 1.750