1541
1
GB
Oil burner
G2
CODE
3742611
TYPE
426T1
TECHNICAL FEATURES
For use on hot air generator the burner must be fitted with control box type 539SE.
Burner with CE marking in conformity with EEC directives: EMC89/336/EEC, Low Voltage 73/23/EEC,
Machines 89/392/EEC and Efficiency 92/42/EEC.
The burner meets protection level of IP 40, EN 60529.
DIN Certification No. : 5G329/94 as EN 267.
Thermal power – output 14.2 – 30 kW 1.2 – 2.5 kg/h
Fuel
Gas oil, max. viscosity at 20
°
C: 6 mm
2
/s (1.5
°
E)
Electrical supply
Single phase, 230V
±
10%
~
50Hz
Motor Run current 0.65A 2850 rpm 298 rad/s
Capacitor
4
m
F
Ignition transformer Secondary 8 kV 16 mA
Pump Pressure 7 – 15 bar
Absorbed electrical power 0.165 kW
1 Return line
2 Suction line
3 Gauge connection
4 Pump pressure regulator
5 Vacuum gauge connection
6 Screws fixing air-damper
7 Hydraulic jack with air-damper
8 Lock-out lamp and reset button
9 Flange with insulating gasket
EQUIPMENT
Quantity Description
2
1
2
1
Flexible pipes with nipples
Flange with insulating gasket
Screws and nuts for flange
Screw with two nuts for flange
5