72
SERVICE INFORMATION 2/2
PARAMETER DISPLAYSERVICE
CALL
ERROR
CODE
MAIN ACTUAL TEMP. 26°C
TANK ACTUAL TEMP. 55°C
SMART GRID RUNNING TIME 0 Hrs
The DISPLAY function is used to set the in-
terface:
SERVICE INFORMATION 1/2
PARAMETER DISPLAYSERVICE
CALL
ERROR
CODE
TIME 12:30
DATE 08-08-2018
LANGUAGE EN
BACKLIGHT ON
ENTER
SERVICE INFORMATION 2/2
PARAMETER DISPLAYSERVICE
CALL
ERROR
CODE
SCREEN LOCK TIME 120 SEC
SMART GRID RUNNING TIME 2 Hrs
BUZZER ON
ON/OFF
Use to enter and use , , ,
to scroll.
7.8 Operation Parameter
This menu is for installer or service engineer
reviewingtheoperationparameter.
At home page, go to
> OPERATION PA-
RAMETER.
Press . There are nine pages for the ope-
ratingparameterasfollowing.
Use , to scroll.
OPERATION PARAMETER #01
OPERATION PARAMETER #01
OPERATION PARAMETER #01
OPERATION PARAMETER #01
OPERATION PARAMETER #01
ADDRESS 1/9
ADDRESS 2/9
ADDRESS 3/9
ADDRESS 4/9
ADDRESS 5/9
ONLINE UNITS NUMBER 1
OPERATE MODE COOL
SV1 STATE ON
SV2 STATE OFF
SV3 STATE OFF
PUMP_I ON
PUMP_O OFF
PUMP_C OFF
PUMP_S OFF
PUMP_D OFF
PIPE BACKUP HEATER OFF
TANK BACKUP HEATER ON
GAS BOILER OFF
T1 LEAVING WATER TEMP. 35°C
WATER FLOW 1.72m3/h
HEAT PUMP CAPACITY 11.52kW
POWER CONSUM 1000kWh
Ta ROOM TEMP. 25°C
T5 WATER TANK TEMP. 53°C
Tw2 CIRCUIT2 WATER TEMP. 35°C
T1S’ C1 CLI. CURVE TEMP. 35°C
T1S2’ C2 CLI. CURVE TEMP. 35°C
TW_O PLATE W-OUTLET TEMP. 35°C
TW_I PLATE W-INLET TEMP. 30°C
Tbt1 BUFFERTANK_UP TEMP. 35°C
Tbt2 BUFFERTANK_LOW TEMP. 35°C
Tsolar 25°C
IDU SOFTWARE 01-09-2019V01