E07: Carriage motor or left side micro switch
Electric check:
-
Check the fuse of the carriage clamp
-
Check the inverter if it shows an error than switch of the machine and wait
at least 2 minutes and switch on again. In case the error does not
disappear, the inverter broken.
-
Check the micro switch contact.
-
Check the right side micro switch, because it still give signal.
Mechanical check:
-
Check the position of the micro switch switching arm, because it does not
give activate the micro switches.
-
Check the gears and chain.
-
Check if there is any mechanical blockage of the carriage clamp.
E08: Heating plate temperature sensor
Electric check:
- Check the connection of the heating senor, if the problem still exists,
replace the heating sensor
- If the heating senor is broken, than on the display
1010
o
C appear
constantly.
E09: Glue tank temperature sensor
Electric check:
- Check the connection of the heating senor, if the problem still exists,
replace the heating sensor
- If the heating sensor is broken, than on the display
1010
o
C appear