EasyManua.ls Logo

Rigol DL3000

Rigol DL3000
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 2 Specifications Test RIGOL
DL3000 Performance Verification Manual
Test Record Forms:
Table 2-1 Test Record Form of DL3021 CC Programming Accuracy and Readback
Accuracy
Model
DL3021 (150 V/40 A)
The current range is 40 A.
Specification
Programming Accuracy
± (0.05%+0.02 A)
Readback Accuracy
± (0.05%+0.02 A)
DL3021 Setting
Current
I
L
[1]
Test Result
U
1
I
1
=U
1
/R
M
[2]
I
2
Programming Accuracy: |I
1
- I
L
[1]
|
Readback Accuracy: |I
2
- I
1
|
DL3021 Setting
Current
I
0
[3]
Test Result
U
2
I
3
=U
2
/R
M
[2]
I
4
Programming Accuracy: |I
3
- I
0
[3]
|
Readback Accuracy: |I
4
- I
3
|
The current range is 4 A.
Specification
Programming Accuracy
± (0.05%+0.002 A)
Readback Accuracy
± (0.05%+0.002 A)
DL3021 Setting
Current
I
L
[1]
Test Result
U
1
I
1
=U
1
/R
M
[2]
I
2
Programming Accuracy: |I
1
- I
L
[1]
|
Readback Accuracy: |I
2
- I
1
|
DL3021 Setting
Current
I
0
[3]
Test Result
U
2
I
3
=U
2
/R
M
[2]
I
4
Programming Accuracy: |I
3
- I
0
[3]
|
Readback Accuracy: |I
4
- I
3
|
Note
[1]
: indicates the low current value of the input channel.
Note
[2]
: R
M
= 0.01 Ω.
Note
[3]
: indicates the rated current of the input channel.