REU-2532W Series 39 Rinnai
2) Is the flame rod normal ? Error “72” is displayed
Checking the flame rod.
a. # Detach the flame rod terminal C
1
, and
re-attempt operation.
(“72 is displayed)
Proceed to check item 3 below.
(no “72” displayed)
Inspect flame rod wiring for current leak and
inspect flame rod for carbon build-up.
Measure resistance between the flame rod
Terminal C
1
and the appliance earth.
Normal: 1 M or more.
If normal, replace the PCB unit.
Faulty: Replace the flame rod.
See page 43 for additional information and
reading pertaining to the flame rod.
3) Is the water temperature thermistor normal ?
If error “32” is displayed, check the water
temperature thermistor.
a. # Disconnect connectorB
5
, and measure
resistance of the white ~ white wires.
Resistance > 1 M = open circuit.
Resistance < 1 = short circuit.
Normal: Proceed to check item 4 on the
next page.
Faulty: Replace the water temperature
thermistor.
See page 44 for additional information and
reading pertaining to the temperature
thermistor. .

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rinnai Continuum REU2532-W Series and is the answer not in the manual?

Rinnai Continuum REU2532-W Series Specifications

General IconGeneral
BrandRinnai
ModelContinuum REU2532-W Series
CategoryWater Heater
LanguageEnglish

Related product manuals