Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in
your building.
Immediately call your gas supplier from a neighbor’s phone.
Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire
department.
Installation and service must be performed by a qualified
installer, service agency or the gas supplier.
WARNING: If the information in these instructions is not
followed exactly, a fire or explosion may result causing
property damage, personal injury or death.
Operation and Installation Manual
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
Table of Contents ....................2
Consumer Safety Information ..4
Operating Instructions..............5
Maintenance ............................12
Error Codes .............................13
Installation Instructions ............17
Consumer Support...................42
R50LSi ............... REU-VA2019FFUD
R75LSi ............... REU-VA2528FFUD(A)
R94LSi ............... REU-VA2535FFUD
R98LSi ............... REU-VA3237FFU
R98LSi-ASME.... REU-VA3237FFU-ASME
Direct Vent Tankless Water Heater
ANS Z21.10.3
CSA 4.3
FOR INDOOR APPLICATIONS ONLY
Register your product at www.rinnairegistration.com or
call 1-866-RINNAI1 (746-6241)

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Rinnai R98LSI and is the answer not in the manual?

Summary

Emergency Safety Procedures

What to Do If You Smell Gas

Instructions on immediate actions to take if gas is detected.

Specifications

Consumer Safety Information

Safety Definitions

Defines safety alert symbols and hazard levels (DANGER, WARNING, CAUTION).

Safety Behavior and Practices

Guidelines for safe operation and handling of the appliance.

Safety Features

Details built-in safety mechanisms like overheat and flame failure protection.

Description of Operation

Operating Instructions

Features Available on Temperature Controllers

Lists and describes features of various Rinnai temperature controllers.

Temperature Controllers - Models

Details the MC-91 and MC-502RC wireless temperature controllers and their features.

Temperature Controllers - Models

Details the BC-100V and MC-100V temperature controllers and their features.

Setting the Temperature

Explains how to set the desired water temperature using the controller, with safety warnings.

Temperature Options Without a Temperature Controller

Describes how to set temperatures using dip switches when no controller is installed.

Temperature Ranges

Lists available temperature settings for different Rinnai models.

Setting the Sound Volume (Voice Prompt)

How to adjust the voice prompt volume on MC-100V and BC-100V controllers.

Using the Water Smart; Bath Fill Function

Explains the bath fill feature exclusive to the BC-100V controller.

Setting the Water Volume

How to set the desired water volume for the bath fill function.

Setting Controller to Mute

How to enable or disable controller key press beeps.

Setting the Clock

Instructions for setting the clock on the MC-100V controller.

OPERATING INSTRUCTIONS

General steps for safely operating the Rinnai water heater.

TO TURN OFF GAS TO APPLIANCE

Procedure for safely shutting off the gas supply to the appliance.

Maintenance

Cleaning

Procedure for cleaning the appliance's internal and external components.

Lime; Scale Build-up

Addresses error codes related to scale and how to flush the heat exchanger.

Vent System

Snow Accumulation

How snow accumulation can affect the vent system and appliance operation.

Visual Inspection of Flame

Guidance on inspecting the flame pattern for satisfactory operation.

Error Codes

Trouble Shooting for Common Issues

Accessing Operating Information

How to access recent error codes and operating data via the controller.

Water Quality

Discusses the importance of water quality and lists acceptable levels for various minerals.

Flushing the Heat Exchanger (Error Code: LC or 00)

Step-by-step procedure to flush the heat exchanger to resolve scale build-up.

Installation Instructions

General Instructions

Key guidelines and warnings for installers, including code compliance and material usage.

Clearances from Appliance

Specifies required clearances around the appliance for safety and service access.

Attachment of the Water Heater

Instructions on how to securely mount the water heater to the wall.

Electrical Connection

Requirements for connecting the water heater to a 120 VAC power source.

Gas Piping

Guidelines for safe and proper gas supply line installation.

Pipe Sizing Procedure - Example

Provides a step-by-step example for correctly sizing gas supply lines.

Water Piping

General Instructions

Guidelines for water line connections, including material approvals and purging.

Pressure Relief Valve

Requirements and installation guidelines for the pressure relief valve.

Recommended Piping for Basic Installation

Diagram and equipment list for a standard basic piping installation.

Recommended Piping for Circulation Systems

Piping arrangement for residential and commercial circulation systems to maintain full warranty.

Optional Piping for Circulation Systems

Details optional piping for circulation systems, noting warranty implications.

Freeze Protection

Freeze Protection Piping

Illustrates piping configurations for freeze protection, including solenoid valves.

Venting Instructions

Intake; Exhaust Guidelines

Rules for installing intake and exhaust vent systems for direct vent appliances.

Condensate

Instructions to prevent condensate damage to the heat exchanger.

Maximum Vent Length

Table and instructions for determining maximum vent length based on elbows.

Flue Terminal Clearances (ANS Z21.10.3 • CSA 4.3)

Specifies required clearances for vent terminals in Canadian and US installations.

Additional Clearances - Vent Terminal

Details specific clearances for vent terminals, especially concerning corners and other terminals.

Flue Installation - Concentric Venting (R50 LSi, R75 LSi, R85 LSi)

Instructions for horizontal and vertical flue terminations using concentric venting.

Flue Installation (R98 LSİ, R98 LSi-ASME)

Specific instructions for installing venting for R98LSi models.

Air Intake Assembly

Details the components and connection of the air intake system.

Horizontal with Concentric Termination

Illustrates horizontal vent termination with concentric components for R98LSi models.

Vertical Terminations

Illustrates vertical vent terminations for R98LSi models, including rain prevention.

Vent Products

Listed and Tested Vent Products for R50 LSi, R75 LSi, R94 LSi

Lists certified vent products for specific Rinnai models.

Listed and Tested Vent Products for R98 LSi, R98 LSi-ASME

Lists certified vent products for R98LSi models.

Vent Manufacturer Contact Information for Installation Instructions and Parts Lists:

High Altitude Installations

Connecting Multiple Water Heaters

Guidelines

Important considerations when connecting multiple water heaters, including accessory use.

Temperature Controller Installation

Location

Recommended placement guidelines for temperature controllers to ensure optimal performance and visibility.

Configurations

Details on how multiple controllers can be configured and connected.

Mounting the Controller

Step-by-step instructions for physically mounting the temperature controller to the wall.

Cable Lengths and Size

Technical Data

Pressure Drop Curve

Graph showing pressure loss versus water flow rate for different models.

Outlet Flow Data

Graph showing water flow rate versus temperature rise for different models.

Space Heating

Temperature Setting

Recommendations for setting temperature when used for space heating.

Pumps

Guidance on selecting and using pumps for circulation systems.

Replacement

Iron Components

Warning against using iron components in space heating applications.

Dimensions

Ladder Diagram

Consumer Support

Warranty Information

Section for recording purchase and installation details for warranty purposes.

Limited Warranty

Details what is covered under the Rinnai warranty and for how long.

Rinnai R98LSI Specifications

General IconGeneral
Fuel TypeGas
Gas TypeNatural Gas or Propane
Maximum Flow Rate9.8 GPM
Energy Factor0.95
GPM at 35°F Rise9.8 GPM
VentingConcentric or Twin-Pipe PVC/CPVC
Ignition TypeElectronic
CategoryTankless
Maximum BTU Input199, 000 BTU/h
Temperature Range98°F to 140°F
Electrical Requirements120V, 60Hz
Dimensions18.5
Warranty5 years on parts
Minimum BTU Input15, 000 BTU/hr