The Rinnai Portable Room Air Conditioner (Models: RPC26WA, RPC35WA, RPC41WA) is a versatile appliance designed to provide cooling, dehumidifying, and fan-only operation for indoor spaces. This manual outlines its installation, operation, and maintenance, emphasizing safety and optimal performance.
The Rinnai Portable Room Air Conditioner offers three primary operational modes:
A notable feature is the SLEEP Function, which intelligently adjusts the set temperature over a 10-hour period to maintain comfort and save energy. After 10 hours, the appliance resumes normal operation. The appliance also stores the most recent basic operational settings in its memory, which are available upon restart if the unit remains connected to the mains power supply.
| Model | RPC26WA | RPC35WA | RPC41WA |
|---|---|---|---|
| Power Supply | 220-240V~/50 | ||
| Maximum Input Power | 1200 W | 1600 W | 2000 W |
| Dimensions - Net (H x W x D) | \multicolumn{3}{c | }{798 x 475 x 417 mm} | |
| Dimensions - Packing (H x W x D) | \multicolumn{3}{c | }{890 x 520 x 450 mm} | |
| Weight | \multicolumn{3}{c | }{32 kg} | |
| Nominal Cooling Capacity | 2.60 kW | 3.55 kW | 4.10 kW |
| Rated Input Current | 4.45 A | 5.95 A | 7.89 A |
| Rated Input Power | 1.00 kW | 1.34 kW | 1.78 kW |
| Refrigerant Type | \multicolumn{3}{c | }{R410A} | |
| Refrigerant Volume | 350 g | 520 g | 520 g |
The appliance is fitted with a 1.2m flexible 2-pin cord, suitable for connection to an Australian 10 Amp socket outlet (220-240V 50Hz). The maximum exhaust duct extension is 1.8m.
The appliance features a user-friendly control panel with indicators for fan speed, mode, temperature display, and various functions like TIMER, SLEEP, and SWING. Temperature settings can be adjusted using dedicated buttons, and fan speed can be selected from LOW, MED, or HIGH. The ON/OFF button controls the appliance's power.
For installation, the unit requires a minimum clearance of 500mm from walls or other appliances and must be placed on a flat, dry surface with easy access to a power point. The air outlets and ducting system must not be obstructed.
Duct Assembly: The exhaust duct (extends to 1.8m) connects to the appliance via a duct-to-unit adaptor and can be fitted with either a window exhaust duct adaptor or a wall exhaust adaptor. Window Installations: An adjustable window slide kit (minimum 675mm, maximum 1250mm) is provided to fit most standard vertical and horizontal window applications. Foam draft sealing strip is recommended for optimal sealing. Semi-Permanent Wall Installation: A wall flange kit is supplied for semi-permanent wall installations, which must be completed by an authorised person in compliance with local building codes and OH&S guidelines.
Condensate Drainage: The appliance has an inbuilt condensate tank. When the tank reaches capacity, the "P1" code will appear on the display, and the unit will stop operating. Users must drain the condensate water via the Drain Tray Outlet (12) into a shallow tray (at least 1 litre volume). Alternatively, a fixed condensate drain hose (20) can be attached to either Drain Outlet 1 (7) or Drain Tray Outlet (12) for continuous drainage into a drain tray or waste outlet. It's crucial that the drainage point is lower than the outlet point. The condensate is not potable.
Regular maintenance is essential for optimal performance and longevity.
The manual provides a troubleshooting guide for common issues:
Contact Rinnai if there's a burning smell, strange sounds, or if a circuit breaker is tripped or a fuse blown during operation. The appliance should only be serviced by Rinnai or an appointed service agent. Rinnai recommends servicing the appliance at least every 2 years.