KB Series Manual 25
Installaon of PVC/CPVC Vent and Intake Air Piping:
Note the correct posion of combuson air inlet and gas ue outlet, as these are interchangeable. For the
correct posion and design of the twin pipe gas ue outlet and combuson air inlet refer to the installaon
instrucons supplied with the appliance.
The adaptor as supplied requires no addional parts to be used with standard 3” 3rd party solid core PVC/
CPVC pipes; refer to gure below for required parts for 3” PVC/CPVC assembly conguraon.
Conversely, the concentric to twin pipe adaptor require 2 addional (4”x 3” Flush – Schedule 40 PVC) bushing
to be used with 4” PVC/CPVC assembly conguraon (refer to gure below).
Failure to correctly assemble the components according to these instrucons may result in property damage,
serious injury, or death.