EasyManua.ls Logo

Rinnai V65e - How to use the Temperature Controller

Rinnai V65e
80 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
30 Value Series Manual
How to use the Temperature Controller
The MC-91-2 controller is the standard temperature
controller that is supplied with the water heater. On
indoor models it is integrated into the front panel.
The MCC-91-2 controller is for hydronic applicaons
requiring higher temperatures. When the MCC-91-2
controller is connected, these higher temperatures
are available on all controller models in the system.
Refer to the secon on temperature ranges.
DO NOT repeatedly operate the water heater and
then use a hot water tap while the controller is
turned o. Operang the water heater in this way to
alternately produce hot water may cause water to
condense on the outside of internal parts and
accumulate in the water heater cabinet.
Dimensions (inches): 3.5 W x 4.75 H x 0.75 D
Temperature
Display
Priority
Indicator
Priority
Button
ON/OFF
Button
In Use
Indicator
Temperature
Selection
MC-91-2US
Before operang, smell all around the appliance
area for gas. Be sure to smell next to the oor
because some gas is heavier than air and will sele
on the oor.
Keep the area around the appliance clear and free
from combusble materials, gasoline, and other
ammable vapors and liquids.
Always check the water temperature before
entering a shower or bath.
Do not use this appliance if any part has been under
water. Immediately call a licensed professional to
inspect the appliance and to replace any part of the
control system and any gas control which has been
under water.
Should overheang occur or the gas supply fail to
shut o, turn o the manual gas control valve to
the appliance.
Do not adjust the DIP switch unless specically
instructed to do so.
Do not use an extension cord or an adapter plug
with this appliance.
Any alteraon to the appliance or its controls can
be dangerous and will void the warranty.
If you install this water heater in an area that is
known to have hard water or that causes scale build
-up the water must be treated and/or the heat
exchanger ushed regularly. Rinnai provides a
“Scale Control System” that oers superior lime
scale prevenon and corrosion control by feeding a
blend of control compounds into the water supply.
Damage and repair due to corrosive compounds in
the air is not covered by warranty.
Keep the air intake locaon free of chemicals such
as chlorine or bleach that produce fumes. These
fumes can damage components and reduce the life
of your appliance. Damage and repair due to scale
in the heat exchanger is not covered by warranty.
WARNING

Table of Contents

Related product manuals