NOTES: Command words are not case sensitive. A separator between command words
may be used (or not). To receive an acknowledgement reply, add RP to the end of an SMS
command.
Full Arm: code + A (Example: 1234A)
Get system status: code + ST
Bypass Zone: code + B + zone number
Group Arm: code + G + select group A--D
Un-bypass Zone: code + UB + zone
number
View last alarm : code + AL
Partition Full Arm: code + A: + partition number
Change FM number: code +
FMPHONE +
FM serial number + NEW + new
phone number
Partition Home Arm: code + H: + partition number
Activate Output: code + UOON + UO
number
Deactivate Output: code + UOOFF +
UO number
Multiple Partition Full/Home Arm: code + A/
H: + partition number A, + partition number B, +
partition number C, etc.
Get SIM credit level: code + CR
Partition Disarm: code + D: + partition number
Get SIM credit level: code + CR
Multiple Partition Disarm: code + D: + partition
number A, + partition number B, + partition
number C, etc.
LED Indicators ā Elegant Keypad
Power LED
On: Power OK.
Off: No power
Rapid flash: System trouble.
Slow flash: System is
programming
Ready LED
On: Ready to arm
Off: Not ready to arm
Slow flash: Ready to arm
while entry/exit zone is
open
Arm LED
On: System in fully armed
mode
Off: System disarmed
Rapid flash: Alarm
Slow flash: System in Exit
Delay
Partial Arm / Bypass
LED
On: System in partially-
armed or zone-bypassed
mode
Off: No bypassed zones
Tamper LED
On: Tamper alarm
Off: No tamper alarm
Fire LED:
On: Fire alarm
Off: No fire alarm
Flash: Fire circuit trouble