6. PROGRAM CONTROL
IMR02L04-E3
6-29
6.11.3 Setting procedure
How to conduct Pattern copy
[Example: Copy the data of Pattern 1 to Pattern 2.]
The next parameter displays instead of YES/NO display when the same value or “0” is set to the
numbers of Copy source and Copy destination.
How to conduct Data clear
To conduct Data clear, set “9999.”
Tip: It is easier to set “10000” first and press the
key to reduce the number by 1 rather than setting “9”
to each place.
PV
L COPY
M:S
SV
FIX00000‹00
Pattern copy
Copy destination
number
PV
L COPY
M:S
SV
FIX00000‹0 0
PV
L COPY
M:S
SV
FIX00001‹0 0
Set “1.”
PV
L COPY
M:S
SV
FIX00001‹00
Copy destination number
flashes.
Copy source number flashes.
Press twice
PV
L COPY
M:S
SV
FIX00001‹02
Set “2.”
PV
L COPY
M:S
SV
01‹02001‹No
“NO” displays.
Press the key to
switch to YES.
PV
L COPY
M:S
SV
01‹02001YES
“YES” displays.
Copy is available
Press the key to
conduct Pattern copy.
Setting end
Copy source
numbe
r
PV
L0CLR
M:S
SV
FIX00000000
Data clea
r
Flash 10 thousands place.
PV
L0CLR
M:S
SV
FIX00000000
PV
L0CLR
M:S
SV
FIX00010000
Set “1.”
Several
times
PV
L0CLR
M:S
SV
FIX00010000
Flash one place.
PV
L0CLR
M:S
SV
FIX00009999
“NO” displays.
Press the key to
switch to YES.
PV
L0CLR
M:S
SV
FIX000000NO
“YES” displays.
Data clear is available.
PV
L0CLR
M:S
SV
FIX00000YES
Setting end
Press the
key to
conduct Data clear.
Display “9999”

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the RKC INSTRUMENT PF Series and is the answer not in the manual?

RKC INSTRUMENT PF Series Specifications

General IconGeneral
BrandRKC INSTRUMENT
ModelPF Series
CategoryController
LanguageEnglish

Related product manuals