Process/Temperature Controller RB100/400/500/700/900
• Quick start code 2 tells the factory to ship with each parameter preset to the values detailed as specified by the customer.
Quick start code is not necessarily specified when ordering, unless the preset is requested.
These parameters are software selectable items and can be re-programmed in the field via the manual.
Quick Start Code
Maximum number of digital outputs (DO) by combinations of output (OUT1 and OUT2)
Current
output
Voltage
output
V
(20 mA)
V
(10 mA)
M, T, D
OUT2 (Including transmission output)
No OUT2
output
( : Represents selection of digital outputs
-DO3 and DO4 are not available.)
M, T, D
V (Load: 10 mA)
V (Load: 20 mA)
Current output
Voltage output
4
4
4
4
4
4
4
4
2
4
2
2
4
4
4
422 224
422 224
4
2
2
*1 When the instrument has two digital outputs
(DO1 and DO2) and no OUT2 output, "V" type
output (load: 40mA) can be specified for OUT1.
OUT1
*1
N
N
1
2
3
4
5
6
7
N
N
N
A
Event Code Table
(Programmable)
B
C
D
E
F
G
H
J
K
L
V
2
1
W
4
5
3
Q
R
T
U
Y
Z
X
FAIL
Deviation High
Deviation Low
Deviation High with Hold
Deviation Low with Hold
Process Low
Process High
Process High with Hold
Set value High
Set value Low
Deviation High/Low
(Common high/low setting)
Deviation High/Low (Individual high and low settings)
Band
(Common high/low setting)
Band (Individual high and low settings)
Deviation High/Low with Hold
(Common high/low setting)
Deviation High/Low with Alarm Hold (Individual high and low settings)
Deviation High with Alarm Re-hold
Deviation Low with Alarm Re-hold
Deviation High/Low with Re-Hold (Common high/low setting)
Deviation High/Low with Alarm Re-Hold (Individual high and low settings)
Process Low with Hold
Loop break alarm
Heater break alarm (HBA)
RUN status
Event Type
Code
Quick start codeSpecifications
Digital output 1 (DO1)
(Event 1 type)
Digital output 2 (DO2)
(Event 2 type)
Digital output 3 (DO3)
(Event 3 type)
Digital output 4 (DO4)
Digital input (DI)
(Event 4 type)
None
See event code table
None
See event code table
None
See event code table
None
See event code table
SV1 to SV4 select
SV1/SV2 select + STOP/RUN
SV1 to SV2 select + MANUAL/AUTO
SV1 to SV2 select + Alarm interlock reset
STOP/RUN + MANUAL/AUTO
STOP/RUN + Alarm interlock reset
MANUAL/AUTO + Alarm interlock reset
None
Example of Model Code and Quick start code
ABNN 5
Digital output 1
Digital input
Digital output 2
Digital output 3
Digital output 4
STOP/RUN + MANUAL/AUTO
RB500
F K09 8 Y 2 1
1
9
Model Code
4 to 20mA
0 to 10V
2 points (DO1+DO2)
PID control (Revere action)
K 0.0 to 400.0°C
Control : PID control for Heating, (Output : 4 to 20mA DC)
Input : Thermocouple K 0.0 to 400.0°C
*1: On the RB100, this can be specified when event 3 (Code : "P") is selected
in output 2.
*2: On the RB100, this is fixed at "none".
*1
*2
Specifications
Digital output (Alarm) : 2 point (Deviation High, Deviation Low)
Digital input : 2 point (STOP/RUN, MANUAL/AUTO)
Analog retransmission output : 0 to 10V DC
Control Method
Input and range
Output 1 (Heat output)
Output 2
(Analog Retransmission output)
Digital output (Alarm output)
Specify quick start code (DI/DO type)
Power
Supply
Waterproof/
Dustproof
CT input
Case color
Communication
/Y
Instrument version
Quick start code
Deviation High
Deviation Low
None
None
Output of the communication monitoring result
7
4
6
RB_02E