Rear Terminals
Process/Temperature Controller RB100/400/500/700/900
7
8
9
10
11
12
1
2
3
4
5
6
19
20
21
22
23
24
13
14
15
16
17
18
7
8
9
10
11
12
1
2
3
4
5
6
19
20
21
22
23
24
13
14
15
16
17
18
RB900
RB500
RB700
RB400
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
RB100 RB100
5.5
NO
NO
COM
(DO2)
(DO1)
(OUT2)
or
(AO)
(OUT1)
(1) (2)
A
B
B
1
2
3
4
5
6
7
8
9
11
10
12
100 to 240V
L
N
24V AC
L
N
24V DC
100 to 240V
L
N
24V AC
L
N
24V DC
NO
(1) (2)
NO
(1)
Triac
(4)(2)
(3)
(3)
NO
(1) (2)
NO
(1) (2)
(*)
13
14
15
16
17
18
19
20
21
23
22
24
1
2
3
4
5
6
CT1
CT2
COM
(1)
(2)
SG
T/R(A)
T/R(B)
SG
T/R(A)
T/R(B)
(DI 1)
(DI 2)
COM
(1)
(2)
(DI 1)
(DI 2)
NO
NO
COM
(DO4)
(DO3)
NO
NO
COM
(DO2)
(DO1)
CT1
CT2
RS-485
RS-485
(*)
(*)
(*)
(1) (2)
A
B
B
(3)
13
14
15
17
16
18
(*)
(*)
(*)
(*)
(*)
7
8
9
11
10
12
Triac
(4)(3)
(OUT1)
Triac
(4)(3)
Triac
(4)(3)
Measuring input
No Contents
No
Contents
Power supply
• Use a solderless terminal for screw size M3, width 5.8mm or less.
(*) Optional
Communication
Digital input
(DI 1, 2)
(*)
Digital input
(DI 1, 2)
(2) Voltage pulse / Current/Voltage
(1) Relay contact output
Relay contact output
(3) SSR (Triac)
(4) Open collector
Control output 1, 2
(OUT1,2) or
Analog retransmission
output (AO)
Digital output 1, 2
(DO1,2)
(1) Thermocouple
(2) RTD
(3) Voltage/Current
Relay contact output
Digital output 3, 4
(DO3,4)
CT1,CT2 input
No
Contents
Power supply
(2) Voltage pulse / Current/Voltage
(1) Relay contact output
(3) SSR (Triac)
(4) Open collector
No
Contents
No
Contents
Communication
Digital input
(DI 1, 2)
CT1,CT2 input
Measuring input
(1) Thermocouple
(2) RTD
(3) Voltage/Current
Relay contact output
Digital output 1, 2
(DO1,2)
(*) Optional
Control output 1, 2
(OUT1,2) or
Analog retransmission
output, Digital output (AO)
(OUT2)
or
(AO)
(RB900 uses 2 unit)
Model Code :
KRB400-36
Model Code :
KRB100-36A
Model Code :
KRB900-36
Model Code : KFB400-58
Model Code :
KCA100-517
Model Code :
KCA700-53
Front Cover
Terminal Cover
Model code
Current transformer for heater break alarm (HBA)
CTL-6-P-N (0 to 30A)
CTL-12-S56-10L-N (0 to 100A)
CTL
-
6
-
P
-
N CTL
-
12
-
S56
-
10L
-
N
(Unit : mm)
φ 5.8
14.5
25
21
10
Approx.130
φ 12
M3 Depth 4
40
30
40
7.5
15
Approx.100
Approx.25
KD100-55
φ 3.5
250Ω shunt resistor for current input
Model code
Accessory
7
8
9
1
2
3
4
5
6
16
17
18
10
11
12
13
14
15
25
26
27
19
20
21
22
23
24
19
20
21
22
23
24
25
26
27
1
2
3
4
5
6
7
8
9
NO
NO
DO3
DO4
(1) (2) (3)
A
B
B
SG
T/R(A)
T/R(B)
COM
DI2
DI1
10
11
12
13
14
15
16
17
18
NO
NO
DO1
DO2
CT1
CT2
COM
COM
COM
19 20
13 14 15 16 17
18
21
22
23
24
7
8
9
10
11
12
1
2
3
4
5
6
No Contents No Contents
No Contents
100 to 240V
L
N
24V AC
L
N
24V DC
Power supply
(2) Voltage pulse / Current/Voltage
(1) Relay contact output
(3) SSR (Triac)
(4) Open collector
Control output 1, 2
(OUT1,2) or
Analog retransmission
output (AO)
(OUT2)
or
(AO)
(OUT1)
NO
(1) (2)
NO
(1)
Triac
(4)(2) (3)
Triac
(4)(3)
(*)
Relay contact output
Digital output 3, 4
(DO3,4)
RS-485
(*)
Communication
(*)
CT1,CT2 input
(*)
Relay contact output
Digital output
1, 2 (DO1,2)
Measuring
input
(1) Thermocouple
(2) RTD
(3) Voltage/Current
RB400/RB500/RB900
RB700
RB400/500 RB100
RB40/500
RB100
RB900
RB900
RB700
8
RB_02E

Other manuals for RKC INSTRUMENT RB100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the RKC INSTRUMENT RB100 and is the answer not in the manual?

RKC INSTRUMENT RB100 Specifications

General IconGeneral
BrandRKC INSTRUMENT
ModelRB100
CategoryTemperature Controller
LanguageEnglish

Related product manuals