EasyManuals Logo

RKC INSTRUMENT RB100 Manual

RKC INSTRUMENT RB100
8 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #5 background imageLoading...
Page #5 background image
Process/Temperature Controller RB100/400/500/700/900
Output signal code table
Input range code table
Model and Suffix Code
N
1
F
D
G
A
W
RB900 (96 X 96mm, 1/4 DIN)
RB400 (48 X 96mm, 1/8 DIN, Vertical type)
RB500 (96 X 48mm, 1/8 DIN, Horizontal type)
RB100 (48 X 48mm, 1/16 DIN)
N
A
3
4
N
1
N
N
1
2
4
N
P
S
T
U
N
5
6
A
B
C
*1, *2
*1 When control method is selected for PID control (Code : F, D), output 2 is available for analog retransmission output.
*2 On the RB100, the event 3 output function can be specified for output 2.
*3 The number of DO points is limited in some combinations of OUT1 and OUT2 (control output) types.
PID control with AT (Reverse action)
PID control with AT (Direct action)
Heat/Cool PID control with AT
Heat/Cool PID control with AT for extruder (Air cooling type)
Heat/Cool PID control with AT for extruder (Water cooling type)
Control Method
Input and range
See Input range Code Table
See Output 1 Code Table
See Output 2 Code Table
Not supplied
Not supplied
Not supplied
Not supplied
Output 1 (OUT1)
Output 2 (OUT2)
(Control output or analog retransmission output (AO)
(Control output)
24V AC/DC
100 to 240V AC
DO 4 points (DO1 to DO4)
DO 1 points (DO1)
DO 2 points (DO1, DO2)
DI 2 points
Digital output
(DO)
CT input
Power Supply
For CTL-6-P-N (0 to 30A) 1 point
For CTL-12-S56-10L-N (0 to 100A) 1 point
For CTL-6-P-N (0 to 30A) 2 point
For CTL-12-S56-10L-N (0 to 100A) 2 point
RS-485 (ANSI/RKC standard protocol)
RS-485 (MODBUS protocol)
RS-485 (ANSI/RKC standard protocol) + DI 2 points
RS-485 (MODBUS protocol) + DI 2 points
Waterproof/
Dustproof
Not supplied
Waterproof/Dustproof protection
Case color
Black case
White case
Version symbol
Instrument version
No quick start code (Default setting)
Specify quick start code (DO type)
Quick start code
Communication/
Digital input (DI)
*3
• When digital output code is "N", cannot be specified.
• When digital output code is "N", cannot be specified.
• When digital output code is "N", cannot be specified.
• When digital output code is "N", cannot be specified.
Available for RB400/900 only
Available for RB400/900 only
Available for RB400/900 only
Specifications
Model and Suffix Code
Y
/ Y
(Field-programmable)
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
0 200°C
0 400°C
0 600°C
0 800°C
0 1000°C
0 1200°C
0.0 400.0°C
0.0 800.0°C
-199.9
+400.0°C
0 800°F
0 1600°F
-328 +2501°F
-100.0 +752.0°F
0 200°C
0 400°C
0 600°C
0 800°C
0 1000°C
0 1200°C
-200 +1200°C
-199.9 +300.0°C
0 800°F
0 1600°F
-328 +2192°F
-199.9 +550.0°F
0 1769°C
0 3216°F
RangeCodeInput
K01
K02
K03
K04
K05
K06
to-200 +1372°CK41
K09
K10
K43
KA1
KA2
KC7
KC8
J01
J02
J03
J04
J05
J06
J15
J07
JA1
JA2
JB9
JC8
R02
RA2
K
(JIS/IEC)
J
(JIS/IEC)
R
(JIS/IEC)
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
-199.9 +649.0°C
-199.9 +200.0°C
-100.0 +50.0°C
-100.0 +100.0°C
-100.0 +200.0°C
0.0 50.0°C
0.0 100.0°C
0.0 200.0°C
0.0 300.0°C
0.0 500.0°C
-199.9 +400.0°F
-199.9
-199.9
-199.9
+200.0°F
+100.0°F
+300.0°F
0.0 100.0°F
0.0 200.0°F
0.0 400.0°F
0.0 500.0°F
-199.9 +649.0°C
-199.9 +200.0°C
-100.0 +50.0°C
-100.0 +100.0°C
-100.0 +200.0°C
0.0 50.0°C
0.0 100.0°C
0.0 200.0°C
0.0 300.0°C
0.0 500.0°C
RangeCodeInput
D01
D02
D03
D04
D05
D06
D07
D08
D09
D10
DA2
DA3
DA4
DA5
DA6
DA7
DA8
DA9
to-199.9 +900.0°FDB2
P01
P02
P03
P04
P05
P06
P07
P08
P09
P10
Pt100
(JIS/IEC)
JPt100
(JIS)
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
0 1769°C
0 3216°F
400 1800°C
0 1820°C
800 3200°F
0 3308°F
0 800°C
0 1000°C
0 1600°F
0 1832°F
0 1200°C
0 1300°C
0 2300°F
0 2372°F
-199.9 +100.0°C
-100.0 +200.0°C
-199.9 +300.0°C
400.0°C
0.0
0.0 600.0°F
-199.9 +300.0°F
-328 +752°F
0 2000°C
0 2320°C
0 4208°F
0 1300°C
0 1390°C
0 2400°F
0 2534°F
RangeCodeInput
S02
SA2
B01
B02
BA1
BA2
E01
E02
EA1
EA2
N01
N02
NA1
NA2
T02
T03
T05
T06
TC7
TC8
TC9
W01
W02
WA4
A01
A02
AA1
AA2
E
(JIS/IEC)
N
(JIS/IEC)
T
(JIS/IEC)
W5Re/W26Re
(ASTM)
S
(JIS/IEC)
B
(JIS/IEC)
PLII
(NBS)
Thermocouple
RTD
2
2
1
1
1
2
*1 : Accuracy is not guaranteed for less than -100
°C
(-146
°
F)
.
*2 : Accuracy is not guaranteed for less than 400
°C
(752
°
F) for Input Type R, S, B, and W5Re/W26Re.
RangeCodeInput
0 to 1V DC
0 to 5V DC
301
401
501
601
701
801
2
1
DC Current • Voltage Group
0 to 10V DC
1 to 5V DC
0 to 20mA DC
4 to 20mA DC
Temperature Input Group
(Field-programmable)
M
V
4
5
6
Code
Output Type
0 to 10V DC
1 to 5V DC
7
8
T
D
Output 1 Code Table
Relay contact output
Voltage pulse output
0 to 5V DC
4 to 20mA DC
0 to 20mA DC
Triac output
Open collector output
M
V
4
5
6
Code
Output Type
0 to 10V DC
1 to 5V DC
7
8
T
D
Output 2 Code Table
Relay contact output
Voltage pulse output
0 to 5V DC
4 to 20mA DC
0 to 20mA DC
Triac output
Open collector output
(Cool side output)
(Cool side output)
(Cool side output)
(Cool side output)
(Cool side output)
(Cool side output)
(Cool side output)
(Cool side output)
(Cool side output)
Code
Output Type
Relay contact output
4 to 20mA DC
0 to 20mA DC
0 to 10V DC
1 to 5V DC
0 to 5V DC
(Event 3 [DO3] output)
(Analog retransmission output [AO])
(Analog retransmission output [AO])
(Analog retransmission output [AO])
(Analog retransmission output [AO])
(Analog retransmission output [AO])
P
R
S
X
Y
Z
Remarks
Only RB100
Only PID control
Only PID control
Only PID control
Only PID control
Only PID control
Maximum number of digital outputs (DO) by combinations of output (OUT1 and OUT2)
-1999 to +9999
(Programmable)
• For current input, connect is a 250Ω
shunt resistor to the input terminals.
Model code : KD100-55
Factory set value
: 0.0 to 100.0
RB700 (72 X 72mm, 3/16 DIN)
5
RB_02E

Other manuals for RKC INSTRUMENT RB100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the RKC INSTRUMENT RB100 and is the answer not in the manual?

RKC INSTRUMENT RB100 Specifications

General IconGeneral
BrandRKC INSTRUMENT
ModelRB100
CategoryTemperature Controller
LanguageEnglish

Related product manuals